CertainTeed Vinyl Siding Installation Guide
Half-Round Shingles
Important
This product is not designed for roof application. It is designed solely for installation on vertical surfaces.
Panels must be installed with nails over a solid substrate with nail holding strength such as plywood, OSB, or existing wood siding (minimum 7⁄16" thick). This product cannot be installed with staples.
NOTE: Each panel must be nailed through the round hole in the center of the nail hem to control the direction of normal expansion and contraction. If you are installing a partial panel and the center nail hole has been cut off, drill a 3/16" hole in the upper center of the panel, and nail through it.
When cutting Cedar Impressions siding, use a
panel temperature
indicatorPanel Spacing at Different Temperatures marks
|
|
|
|
|
|
|
|
|
|
|
| As with any plastic siding, Cedar Impressions expands and | |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| contracts with changes in temperature. For this reason, it is | |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| important that you space the panels according to the panel | |
|
|
|
|
|
|
|
|
|
|
|
| temperature at the time of installation. Failure to provide the | |
|
|
|
|
|
|
|
|
|
|
|
| ||
use these marks on installed panels | proper spacing according to these temperature ranges may | ||||||||||||
result in gaps that are too large or too small, thereby creating | |||||||||||||
for quick alignment of second | the potential for side lock tabs disengaging, panel distortion, | ||||||||||||
or buckling. Spacing of panels previously installed at a different | |||||||||||||
for final panel adjustments | |||||||||||||
temperature does not require adjustment. | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
Each panel has indicator lines that serve as guides for proper spacing between the panels. The indicator lines are on the upper
Space the panels according to the panel temperature at the time of installation.
Note: Many installers use small infrared thermometers to determine panel temperatures.
Panel Temperature | Temperature Indicator Lines |
30° to 40° | Set to 30 line |
41° to 55° | Set halfway between 30 and 65 lines |
56° to 75° | Set to 65 line |
76° to 90° | Set halfway between 65 and 100 lines |
91° to 100° | Set to 100 line |