Section IX - Troubleshooting

 

 

 

 

Probable Causes:

Corrective Action:

 

 

 

 

Low Air Delivery:

 

 

 

EXCESSIVE AIR DEMAND

REEVALUATE AIR DEMAND. INSTALL ADDITIONAL COMPRESSORS

 

AS NEEDED.

EXCESSIVE LEAKS IN THE SERVICE LINES

CHECK SERVICE LINES FOR LEAKS WITH SOAP SUDS. REPAIR AS

 

NECESSARY.

MINIMUM PRESSURE CHECK VALVE

REPAIR OR REPLACE AS NECESSARY.

STUCK

 

LEAKING BLOWDOWN VALVE(S)

CHECK AND REPLACE AS NECESSARY.

PLUGGED AIR INTAKE FILTER

CLEAN OR REPLACE AIR FILTER ELEMENT.

INOPERATIVE LIFT VALVE

CONTACT AN AUTHORIZED QUINCY SERVICE TECHNICIAN FOR

 

REPAIRS.

 

 

 

 

Frequent Air Cleaner Clogging:

 

 

 

COMPRESSOR OPERATING IN HIGHLY

USE REMOTE AIR INTAKE MOUNTING.

CONTAMINATED ATMOSPHERE

 

AIR CLEANER NOT ADEQUATE FOR

USE SPECIALIZED AIR CLEANER. CONTACT AN AUTHORIZED

CONDITIONS

QUINCY SERVICE TECHNICIAN.

 

 

 

 

Frequent Fluid Filter Clogging:

 

 

 

INCORRECT FLUID FILTER

USE GENUINE QUINCY REPLACEMENT FILTERS ONLY.

SYSTEM CONTAMINATION

CLEAN SYSTEM OF ALL DIRT, CORROSION AND VARNISH.

 

 

 

 

High Discharge Air Temperature:

 

 

 

EXCESSIVE AMBIENT TEMPERATURES

MAXIMUM AMBIENT FOR PROPER OPERATION IS LISTED IN DATA

 

SHEET. VENTILATE ROOM OR RELOCATE COMPRESSOR.

INADEQUATE COOLANT FLOW THROUGH

CLEAN COOLER(S). CHECK WATER SYSTEM FOR POSSIBLE

COOLER(S) (WATER-COOLED)

RESTRICTIONS.

INADEQUATE CIRCULATION OF COOLING

CHECK THE COOLER TO ASSURE THERE ARE NO RESTRICTIONS TO

AIR (AIR-COOLED)

FREE CIRCULATION OF COOLING AIR.

 

CHECK FINS OF COOLER FOR DIRT BUILD-UP. IF NECESSARY,

 

CLEAN FINS WITH AIR (WHILE MACHINE IS NOT RUNNING).

 

CHECK FOR HOT AIR RECIRCULATION OR HOT AIR FROM OTHER

 

EQUIPMENT.

Quincy Compressor® - QSD™

73

 

 