Section VIII - Power$ync IIOperation

controller will turn the machine off. If SHUTDOWN is pressed accidentally and the unit is in the process of shutting down but has not yet stopped, the programmed shutdown can be aborted by pressing SHUTDOWN again.

Compressor Settings and Maintenance Displays

The initial Start-up Display (page 43) offers the user the choice to press START (to begin compressor operation) or ENTER (to move to the compressor setup and maintenance menu). Once compressor operation begins, the operator will see one of the Operational Displays (pages 43-44). If ENTER is pressed, the operator will be directed into a variety of setup and maintenance displays which allow changes to operating pressures, mode of operation, date and time, or to check and/or reset maintenance hourmeters. These setup and maintenance options can be accessed at any time during normal compressor operation by pressing ENTER when the controller has an Operational Display showing.

The Setup Menu portion of the Power$ync IIcontrol displays can be divided into several groups; Pressure Settings, Mode of Operation, Maintenance Hourmeters, Modem Communications, Clock and Control Testing.

IMPORTANT

a)If a situation occurs requiring a WARNING message to be displayed, that message will interrupt any active display.

b)ENTER will always accept the displayed data and either move forward to the next display or backward to the previous display, depending on the requirements of the display.

c)If the display does not make reference to ENTER, pressing ENTER will take the operator back to the previous display.

From the initial Start-up Display or any of the Operational Displays, pressing ENTER will call the first Setup Menu.

Mode and Pressure Displays

COMPRESSOR SETUP MENU

MODE AND PRESSURE MENU PRESS F1

MAINTENANCE MENU PRESS F2

PRESS ENTER TO RETURN

Press F1 to access the Mode and Pressure Menu to select Auto Dual, Continuous Run or Network Mode. Press F2 to move into the Maintenance Menu where hourmeters can be checked and set, time and date can be changed and Power$ync IIvalve operation can be checked. Press ENTER to return to the previous display.

F1allows the mode of operation to be selected or changed. For an explanation of the modes of operation refer to pages 32-33.

COMPRESSOR MODE OF OPERATION

AUTO DUAL TIMED STOP

PRESS F1

CONTINUOUS RUN

PRESS F2

NETWORK SCHEDULED ROTATION PRESS F3

Press F1 to access the Auto Dual Configuration Menu. Press F2 to access theContinuous Run Configuration Menu. F3 accesses the Network Configuration Menu. Although it is not displayed in this menu, ENTER can be pressed to return to the previous Setup Menu. Pressing any F key will result in the compressor switching modes of operation as soon as ENTER is pressed.

AUTO DUAL CONFIGURATION

SET LOAD/UNLOAD PRESSURES PRESS F1

SET SHUTDOWN TIMER PRESS F2

The Auto Dual Configuration Menu allows the operator to set various operating parameters for a compressor running in this mode. The compressor comes from the factory with preset parameters based on the information provided on the order. These should only be changed if system conditions are different from those present at the time the order was placed.