Section III - Installation

Clean air is essential for your Quincy compressor. Always select a source providing the cleanest air possible. When an outside air source is used, keep all piping as short and direct as possible.

Table 3-1 – Water Flow

MODEL

50

75

100

 

 

 

 

GPM @ 50°F

10

13

16

 

 

 

 

GPM @ 70°F

12

16

20

 

 

 

 

GPM @ 90°F

15

20

24

 

 

 

 

WATER PRESS

40/100

40/100

40/100

(MAX/MIN)

 

 

 

 

 

 

 

Minimum water quality is listed in Table 3-2. The quality of the cooling water should be tested regularly, especially when using an open cooling tower.

Contact the factory if you plan to use a water/glycol coolant, salt or brackish water.

Table 3-2 – Water Quality

 

ONCE

COOLING

ITEM

THROUGH

TOWER

WATER

WATER

 

 

SYSTEM

SYSTEM

 

 

 

PH AT 77°F (25°C)

6.5 – 8.0

6.5 – 8.0

 

 

 

CONDUCTIVITY AT 77°F

<500

<200

(25°C) (UV/CM)

 

 

 

 

 

TOTAL HARDNESS AS

<200

<50

CACO3 (PPM)

 

 

 

 

 

M-ALKALINITY AS CACO3

<100

<50

(PPM)

 

 

 

 

 

CHLORINE LON;CL (PPM)

<200

<50

 

 

 

SULFURIC ACID IRON; SO4

<200

<50

(PPM)

 

 

 

 

 

TOTAL IRON; FE (PPM)

<1.0

<0.3

 

 

 

SILICA, SIO2 (PPM)

<50

<30

 

 

 

SULFUR ION; S 2 (PPM)

0

0

 

 

 

AMMONIUM ION; NH4+

0

0

(PPM)

 

 

 

 

 

20

Quincy Compressor® - QSD™

 

 