Section IX - Troubleshooting
Probable Causes: | Corrective Action: |
|
|
High Discharge Air Temperature (continued):
INCORRECT FAN ROTATION
BLOCKED WATER FLOW OR AIR FLOW
CLOGGED AIR FILTER
FAULTY SOLENOID VALVE
FAULTY GAUGES
FAULTY INDICATOR
BLOWDOWN VALVE FAILURE
AIREND FAILURE
RTD READING INCORRECTLY
THE FAN SHOULD PUSH AIR THROUGH THE COOLERS. IF INCORRECT, REVERSE FAN MOTOR STARTER LEADS L1 AND L2.
CLEAN COOLER. LOCATE AND CORRECT CAUSE OF CONTAMINATION.
CLEAN OR REPLACE AS NECESSARY.
CHECK AND REPLACE
CHECK AND REPLACE AS NECESSARY.
CHECK AND REPLACE AS NECESSARY.
CHECK AND REPLACE AS NECESSARY. BOTH MUFFLERS SHOULD BE EXHAUSTING AIR DURING UNLOADED OPERATION.
CONTACT AN AUTHORIZED QUINCY SERVICE TECHNICIAN.
CONTACT AN AUTHORIZED QUINCY SERVICE TECHNICIAN.
Compressor does not Unload when there is no Air Demand:
INCORRECT AIR PRESSURE SENSORS | ADJUST TO PROPER SETTING |
SETTING |
|
FAULTY AIR PRESSURE SENSORS | REPLACE SENSORS. |
FAULTY SOLENOID VALVE | REPAIR OR REPLACE AS NECESSARY. |
LEAKS IN CONTROL LINES | CHECK ALL CONTROL LINE FITTINGS AND TUBINGS. |
LEAKS IN SERVICE LINES | CHECK LINES BEFORE MPC VALVE. |
FAULTY LIFT VALVE(S) | REPAIR OR REPLACE AS NECESSARY. |
FAULTY BLOWDOWN VALVE(S) | REPAIR OR REPLACE AS NECESSARY. |
74 | Quincy Compressor® - QSD™ |
|
|