Section VIII - Power$ync II™ Operation
• Introduction to Power$ync II™ (version 1.04)
•
•Single Machine Operational Mode
•Multiple Machine Operational Mode
•Pressure Settings
•Network Installation
•Network Voltage Tests on Power$ync II® Systems
•Network Setup
•
•
•
•Operational Displays
•Compressor Settings and Maintenance Displays
•Cautionary and Shutdown Displays
•Shutdown Log Messages
Introduction to Power$ync II™
!WARNING
Always disconnect and follow
The Power$ync II™ control for the QSD model compressors consists of a
This control uses four pressure transducers and four RTD temperature probes for the computerized controller. The pressure transducers are located in the control panel. Each transducer is plumbed to its own specific location. Pressure is measured at the discharge of stage one, discharge of stage two, and the discharge of the package. Package discharge is located on the customer side of the package check valve. Fluid pressure is also measured.
The RTD temperature probes are installed at the discharge of each compressor stage, at the inlet of stage two and at the discharge of the package.
There is a coolant flow switch to prevent the unit from running if there is no coolant flow. If the unit is shut down by the coolant flow switch, the control will display ‘Emergency Stop Button Pressed’.
Back-up Mode Operation
The Power$ync II™ control on QSD™ compressors has a
The
The
With these settings verified, activate the
1)Disconnect power from the compressor.
2)Open the electrical enclosure door, and turn the selector switch to
3)Close the electrical enclosure door and reconnect power to the compressor.
4)Wait thirty seconds and press START.
Do not switch modes with power on the compressor!
32 | Quincy Compressor® - QSD™ |
|
|