Section II - Description

Back-up Control

The QSDPower$ync IIcontroller is supplied with a back-up control for emergency operations if the electronic control is inoperative. The Back-up Mode is a simplified system of operations and is not intended for long-term operation. When Back-up Mode is selected all power is removed from the Power$ync IIcontrols, thus the indicator lights located on the annunciator panel will be inoperable. The back-up control uses a PLC for the logic circuit. In the Back-up Mode, the PLC monitors several different areas of the unit to ensure they are in the proper ranges for normal operation.

!CAUTION

Under no condition should the QSDbe switched from Power$ync II to Back-up Mode or vice versa without first removing all power to the unit.

!CAUTION

Always inspect for component failure before operating in Back-up Mode. Operating the unit with faulty components may void warranty.

Shutdown Conditions

NOTE

If one of the following conditions occurs at any time the unit will immediately shutdown. The unit should not be restarted until the problem has been corrected.

The fluid pressure does not reach 15 PSI within five

(5)seconds at start-up or does not maintain pressure during normal operation.

The HAT’s are open at start-up or at any time during operation.

The drive or fan contactor overloads trip.

The coolant flow switch does not close within five

(5)seconds after start-up.

The interstage pressure switch does not open within five (5) seconds after start-up (Back-up Mode only).

The second stage pressure switch does not open within five (5) seconds after start-up (Back-up Mode only).

Both the interstage and second stage pressure switches are open at start-up (Back-up Mode only).

The second stage pressure switch does not close within five (5) seconds after the load/unload pressure switch opens and does not reopen within five (5) seconds after the load/unload pressure switch closes (Back-up Mode only).

!WARNING

High voltage could cause death or serious injury. Disconnect all power supplies before opening the electrical enclosure or servicing.