Section VIII - Power$ync IIOperation

The pressures at which the compressor is operating at full load and is unloaded are adjustable by pressing F1at the above configuration menu. The following message will be displayed:

UNLOAD/LOAD PRESSURE SETUP

COMPRESSOR UNLOAD PRESSURE

______

COMPRESSOR LOADED PRESSURE

______

PRESS ENTER TO ACCEPT VALUE

Read Pressure Settings (pages 34-35) before

setting or modifying pressures. When the Unload/ Load Pressure Setup Menu is displayed, the Compressor Unload Pressure setting will be flashing. Use the UP or DOWN arrow keys to change the setting. Once the desired setting is reached, press ENTER to accept. The Compressor Loaded Pressure setting will then begin to flash. Again, use the UP or DOWN arrow keys to change the setting. Press ENTER to accept the Loaded Pressure setting and return to the Auto Dual Configuration Menu .

At the Auto Dual Configuration Menu Press F2 to adjust the delay time. This delay is the time between when a signal is sent to unload the compressor and when a signal is sent to shut the machine down.

AUTO DUAL TIMER SETUP

TIMED STOP DELAY IN MINUTES ______

PRESS ENTER TO ACCEPT VALUE

Before changing this setting from the default setting, read Auto Dual Time Delay (page 33).

Use the UP or DOWN arrow key to change the time setting from the default 10 minutes. When the desired time is displayed, press ENTER to accept the data and return to the Auto Dual Configuration Menu.

Press F2 at the Compressor Mode of Operation Menu to select the Continuous Run Configuration. Under this mode of operation, the compressor will load and unload as system demands are met, but will not time out and shutdown the main motor.

CONTINUOUS RUN CONFIGURATION

SET LOAD/UNLOAD PRESSURES PRESS F1

**************************************

PRESS ENTER TO RETURN

Press F1 to change the load and unload pressures.

UNLOAD/LOAD PRESSURE SETUP

COMPRESSOR UNLOAD PRESSURE

______

COMPRESSOR LOADED PRESSURE

______

PRESS ENTER TO ACCEPT VALUE

Read Pressure Settings (pages 34-35) before

setting or modifying pressures. When the Unload/ Load Pressure Setup Menu is displayed, the Compressor Unload Pressure setting will be flashing. Use the UP or DOWN arrow keys to change the setting. Once the desired setting is reached, press ENTER to accept. The Compressor Loaded Pressure setting will then begin to flash. Again, use the UP or DOWN arrow keys to change the setting. Press ENTER to accept the Loaded Pressure setting and return to the Continuous Run Configuration Menu .

Before making changes to the Network Configuration, read Multiple Machine Operational Mode (page 33).

Press F3 at the Compressor Mode of Operation Menu to access Network Configuration Menu 1. The following display will appear on the screen:

NETWORK CONFIGURATION MENU 1

SET SHUTDOWN TIMER

PRESS F1

SET MACHINE ID

PRESS F2

UP FOR NEXT MENU/DOWN FOR PREVIOUS MENU

There are five Network Configuration Menus in the Power$ync IIsystem. These menus can be accessed by pressing the UP or DOWN arrow keys located to the right of the message display window. Menu 1 allows the operator to adjust the Machine ID and/or the Shutdown Timer setting. Press F1 at Network Configuration Menu 1 to access the Shutdown Timer Setup display.

46