Section IX - Troubleshooting

 

 

 

 

Probable Causes:

Corrective Action:

 

 

Compressor does not revert to Load when Service Line Pressure Drops to Reset Pressure:

 

 

LOOSE WIRING CONNECTION

CHECK AND TIGHTEN WIRING TERMINALS.

FAULTY PRESSURE SENSOR

REPAIR OR REPLACE AS NECESSARY.

FAULTY SOLENOID

REPAIR OR REPLACE AS NECESSARY.

FAULTY TIMER

CHECK AND REPLACE TIMER.

FAULTY LIFT VALVE(S)

REPAIR OR REPLACE AS NECESSARY.

FAULTY BLOWDOWN VALVE(S)

NO AIR SHOULD BE BLOWING OUT FROM THE MUFFLERS DURING

 

LOADED OPERATION.

NETWORK OUT OF SEQUENCE OR

CHECK AND RESET SEQUENCE OR SCHEDULE AS NECESSARY.

SCHEDULE

 

Compressor Will not Time out or Shut down when Unloaded (Auto Dual Only):

LEAKS IN CONTROL LINES

LEAKS IN SERVICE LINES

STORAGE CAPACITY TOO SMALL

LEAKS IN MINIMUM PRESSURE CHECK VALVE

FAULTY AIR PRESSURE SWITCH

FAULTY AIR PRESSURE SENSORS

CHECK AND REPAIR ANY LEAKS.

CHECK PLANT AIR DISTRIBUTION SYSTEM FOR LEAKS.

ADD MORE STORAGE CAPACITY AS CLOSE TO THE COMPRESSOR AS POSSIBLE.

REPAIR OR REPLACE AS NECESSARY.

REPAIR OR REPLACE AS NECESSARY.

REPLACE AS NECESSARY.

Too Rapid Cycling Between Load and Unload:

LEAKS IN CONTROL LINES

CHECK AND REPAIR ANY LEAKS.

WATER OR ICE IN CONTROL LINES

DRAIN LINES, REPLACE AS NECESSARY.

FAULTY AIR PRESSURE SENSORS

REPLACE AS NECESSARY.

STORAGE CAPACITY TOO SMALL

ADD STORAGE CAPACITY (MINIMUM OF THREE GALLONS PER

 

CFM).