Section IX - Troubleshooting
Probable Causes: | Corrective Action: |
|
|
Unscheduled Shutdown (continued): |
|
|
|
HIGH PRESSURE DIFFERENTIAL | CHECK LIFT VALVE, BLOWDOWN VALVE AND MINIMUM PRESSURE |
| CHECK VALVE OPERATION. |
| CONTACT AN AUTHORIZED QUINCY SERVICE TECHNICIAN FOR |
| REPAIRS. |
COOLANT FLOW SWITCH OPEN | CHECK COOLANT |
THERMAL MOTOR OVERLOAD RELAYS | CORRECT THE CAUSE OF THE MOTOR OVERLOADED CONDITION, |
TRIPPING | RESET THE OVERLOAD RELAY AND PRESS THE RESET BUTTON. |
INCORRECT THERMAL OVERLOAD RELAY | CHECK MOTOR NAMEPLATE AND COMPARE TO OVERLOAD RELAY |
SETTING | SETTING. |
LOOSE OVERLOAD CONNECTION | TIGHTEN MOUNTING SCREWS ON THERMAL OVERLOAD. |
LOOSE WIRE CONNECTIONS | CHECK ALL WIRING TERMINALS FOR CONTACT AND TIGHTNESS. |
POWER FAILURE | CHECK POWER SUPPLY AND TRANSFORMER FUSES. |
| CHECK THE POWER SUPPLY, POWER SUPPLY CABLES AND RIBBON |
| CABLE GOING TO DISPLAY BOARD. |
LOW VOLTAGE | CHECK VOLTAGE AND AMPERAGES WHILE OPERATING AT FULL |
| LOAD PRESSURE. |
FAULTY CONTROL RELAY | REPLACE RELAY. |
FAULTY MOTOR | CHECK MOTOR STARTER WIRING BEFORE REMOVING MOTOR. |
| REMOVE MOTOR AND HAVE TESTED AT MOTOR MANUFACTURER |
| REPAIR CENTER. |
FAULTY OR DISCONNECTED RTD | CHECK WIRE CONNECTION BETWEEN RESISTANCE TEMPERATURE |
| DETECTOR AND MICROPROCESSOR BOARD. IF RTD |
| PERFORMANCE IS QUESTIONABLE, CONTACT AN AUTHORIZED |
| QUINCY SERVICE TECHNICIAN. |
FAULTY OR DISCONNECTED PRESSURE | CHECK WIRE CONNECTIONS OF PRESSURE SENSORS. |
SENSORS | REPLACE SENSORS. |
MOTOR OVERLOAD | CORRECT THE CAUSE OF THE OVERLOAD CONDITION. RESET THE |
| OVERLOAD RELAY AND PRESS ENTER. |
REVERSE ROTATION | CHECK FOR PROPER AIREND ROTATION. |
| REDUCE “RAMP” TIME ON REMOTE LOW VOLTAGE OR SOLID |
| STATE STARTERS. |
72 | Quincy Compressor® - QSD™ |
|
|