Section VIII - Power$ync II™ Operation
Detected problems that will not result in an unsafe operating condition but should be corrected as soon as possible include:
NOTICE
DEADBAND DATA ERROR
PRESS F1 TO CLEAR
In Network Mode, an unload pressure setting and a reload pressure setting are required. If the controller cannot find pressure settings that are within a reasonable range during the diagnostic program, it will display this message. To correct the problem, go to Network Menu 1 and select SETUP NETWORK PRESSURES. Confirm the pressure ranges and press ENTER . The display will then change to NETWORK UNLOAD/LOAD PRESSURE SETUP. The current network unload pressure setting will be flashing. Use the UP and DOWN arrow keys (located to the right of the display window) to select the setting. Press F1 to change the setting and press ENTER to accept the settings. This warning is most likely to occur at initial
NOTICE
U19 DATA CHECKSUM ERROR
PRESS F2 TO UPDATE
Power$ync II™ uses a checksum function to confirm the information in the setup memory. If the information in the memory has changed, the checksum number will not be the same. This message indicates that the diagnostic program has detected such a change. There are default values for this information that will allow the Power$ync
II™ computer to operate the compressor if it cannot find the correct checksum number in the setup information. Operation using the default checksum may not be as efficient as operation would be with all correct configuration information entered. Press F2 to install the default checksum into the computer memory and all subsequent restarts will be completed using this default information. To achieve the highest level of efficiency, it is important that the Power$ync II™ computer have the correct configuration data. Your service representative can enter that data and initialize the system.
NOTICE
U19 DATA NOT INITIALIZED
PRESS F2 TO INITIALIZE
The Power$ync II™ computer is programmed with information concerning the configuration of the machine onto which it is installed. This information includes; motor horsepower, type of cooling, type of starting, pressure ranges, etc. Power$ync II™ needs this information to provide the most efficient operation. At
Quincy Compressor® - QSD™ | 41 |
|
|