Section IX - Troubleshooting
Probable Causes: | Corrective Action: |
| |
Excessive Water in Plant Air Distribution System: | |
|
|
CLOGGED MOISTURE SEPARATOR/TRAP | CLEAN OR REPLACE AS REQUIRED. |
INSTALLATION/APPLICATION | CHECK OTHER COMPRESSORS ON SAME SYSTEM. |
FAULTY OR LEAKING COOLER(S) | REPLACE COOLER. |
|
|
|
|
Pressure Relief Valve Exhausting: |
|
|
|
AIR PRESSURE NOT SET CORRECTLY | READJUST AIR PRESSURE SWITCH SO THAT THE COMPRESSOR |
| UNLOADS AT THE DESIRED PRESSURE. |
FAULTY PRESSURE RELIEF VALVE | CHECK RELIEF VALVE FOR CORRECT PRESSURE SETTING. IF |
| VALVE IS STILL LEAKING, REPLACE IT. |
Excessive Fluid in Buffing Air Vent Bowls:
BUFFING AIR PRESSURE REGULATOR NOT CHECK REGULATOR OUTPUT PRESSURE. CHECK FOR HIGH FLUID
SET CORRECTLYLEVEL. CHECK FOR SEAL FAILURE. CONTACT AN AUTHORIZED QUINCY SERVICE TECHNICIAN.
Water in Buffing Air Vent Bowls:
PLUGGED MOISTURE TRAP DRAIN | CHECK AND CLEAN MOISTURE TRAP DRAIN. |
| |
| |
Excessive Fluid in Gearbox Vent Bowl: | |
|
|
CLOGGED MIST ELIMINATOR | REPLACE MIST ELIMINATOR. |
FAULTY CHECK VALVE | REPLACE CHECK VALVE. |
76 | Quincy Compressor® - QSD™ |
|
|