Juniper Networks M10i manual SONET/SDH Interface Alarm Messages

Models: M10i

1 240
Download 240 pages 53.15 Kb
Page 106
Image 106

M10i Internet Router Hardware Guide

Table 16: Chassis Alarm Messages (continued)

Chassis

 

 

Alarm

Component

Alarm Condition

Remedy

Severity

 

 

Reformat internal

 

 

 

flash drive and install

 

 

 

bootable image. If this

 

 

 

fails, replace failed

 

 

 

Routing Engine.

 

 

System booted from hard disk. This

Install bootable image

Yellow

 

alarm only applies if you have an

on internal flash

 

 

optional internal flash drive installed.

drive. If this fails,

 

 

 

replace failed Routing

 

 

 

Engine.

 

Internal flash drive missing in boot list.

Hard disk missing in boot list.

Routing Engine failed to boot.

Temperature The chassis temperature has exceeded 55° C and the fans have been turned on to full speed and one or more fans have failed.

The chassis temperature has exceeded 65° C and the fans have been turned on to full speed.

Replace failed Routing

Red

Engine.

 

Replace failed Routing

Red

Engine.

 

Replace failed Routing

Red

Engine.

 

Check room

Yellow

 

temperature.

 

Check air flow.

 

Check fan tray.

 

Check room

Yellow

 

temperature.

 

Check air flow.

Check fan tray.

The chassis temperature has exceeded 65° C and a fan has failed. If this condition persists for more than 4 minutes, the router shuts down.

The chassis temperature has exceeded 75° C. If this condition persists for more than 4 minutes, the router shuts down.

The temperature sensor has failed.

Check room

Red

temperature.

 

Check air flow.

Check fan tray.

Check room

Red

temperature.

 

Check air flow.

Check fan tray.

Contact technical

Red

support. See

 

“Requesting

 

Support” on page xxiv

 

for more information.

 

Table 17: SONET/SDH Interface Alarm Messages

CLI Message