M10i Internet Router Hardware Guide

4.Align the rear of the CFEB with the guides inside the chassis and slide it in completely.

5.Press the ejector lever at each end of the CFEB inward.

6.Tighten the thumbscrew on each ejector lever (shown in Figure 4) to seat the CFEB firmly in the chassis.

7.Press the offline button on the CFEB faceplate and hold it down until the green LED labeled OUTPUT OK lights steadily, in about 5 seconds.

You can also verify correct CFEB functioning by issuing the show chassis cfeb commands described in “Maintaining the CFEB” on page 73.

Figure 30: Installing a CFEB

Replacing an HCM

The HCM is hot-pluggable, as described in “Field-Replaceable Units (FRUs)” on page 3. For a description of the effect of removing an HCM, see “High-Availability Chassis Manager (HCM)” on page 17. To replace an HCM, perform the following procedures:

Removing an HCM on page 92

Installing an HCM on page 95

Removing an HCM

To remove an HCM, follow this procedure (see Figure 31 and Figure 32):

1.Place an electrostatic bag or antistatic mat on a flat, stable surface.

2.If a Routing Engine is installed in the same row as the HCM you are removing, remove the Routing Engine first. If two Routing Engines are installed, use one of the following two methods to determine which is functioning as master:

Note which of the blue MASTER LEDs is lit on the Routing Engine faceplates.

Issue the following CLI command. The master Routing Engine is designated

Master in the Current state field:

92Replacing an HCM

Page 116
Image 116
Juniper Networks M10i manual Replacing an HCM, Removing an HCM