Crestron | Ethernet/Cresnet Interface | ||
| Leading Specifications of the |
|
|
|
|
| |
| SPECIFICATION | DETAILS | |
|
|
| |
| Power Requirements | 12VDC, external power pack or | |
|
| 24VDC, .25A, 6W, network | |
|
|
| |
| Ethernet Network Type | 10BaseT | |
| Ethernet Network Protocols | TCP/IP, UDP/IP, ICMP (Ping), & CIP | |
|
|
| |
| SIMPL™ Windows® | Version 1.52.00 or later. 1 | |
| Version 51189N.UPZ or later. 2 | ||
| Version 51190X.UPZ or later. 2 | ||
| Version 51190W.UPZ or later. 2 | ||
| Dimensions & Weight | Height: 1.70 in (4.32 cm) | |
|
| Width: 7.07 in (17.95 cm) | |
|
| Depth: 6.32 in (16.06 cm) | |
|
| Weight: 1.87 lb (0.85 kg) |
1Although the
2Filenames for update files have a UPZ extension and can be obtained from the Downloads page (OPSYS Library) of Crestron’s website.
As of the date of manufacture, this unit has been tested and found to comply with specifications for CE marking.
NOTE: This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful interference, and
(2)this device must accept any interference received, including interference that may cause undesired operation.
Cresnet Network Wiring
NOTE: If making category 5 connections to the Cresnet peripherals, refer to the latest revision of the Cresnet Mini Network CAT 5 Interconnect Drawing (Doc. 5819). This document can be obtained from the Downloads page (CABLES and MANUAL Libraries) of Crestron’s website (www.crestron.com). Search for CAT5.PDF. New users are required to register to obtain access to the FTP site.
NOTE: If making modular connections to devices in the Cresnet system, review the latest revision of the Network Modular Cable Requirements (Doc. 5682). This document can be obtained from the Downloads page (CABLES and MANUAL Libraries) of Crestron’s website (www.crestron.com). Search for MODULAR.PDF.
When calculating the wire gauge for a particular Cresnet run, the length of the run and the load factor of each network unit to be connected must be taken into consideration. If Cresnet units are to be
Operations Guide - DOC. 5721 | Ethernet/Cresnet Interface: |