Leading Specifications of the CEN-CN

 

 

 

 

 

 

SPECIFICATION

DETAILS

 

 

 

 

Power Requirements

12VDC, external power pack or

 

 

24VDC, .25A, 6W, network

 

 

 

 

Ethernet Network Type

10BaseT

 

Ethernet Network Protocols

TCP/IP, UDP/IP, ICMP (Ping), & CIP

 

 

 

 

SIMPL™ Windows®

Version 1.52.00 or later. 1

 

CEN-CN Update File

Version 51189N.UPZ or later. 2

 

CNMSX-AV/Pro Update File

Version 51190X.UPZ or later. 2

 

CNRACKX-DP Update File

Version 51190W.UPZ or later. 2

 

Dimensions & Weight

Height: 1.70 in (4.32 cm)

 

 

Width: 7.07 in (17.95 cm)

 

 

Depth: 6.32 in (16.06 cm)

 

 

Weight: 1.87 lb (0.85 kg)

1Although the CEN-CN does not support a program being loaded, the version listed is required by the host control system to support the CEN-CN. The latest software version can be obtained from the Downloads page (SIMPLWIN Library) of Crestron’s website (www.crestron.com). New users are required to register in order to obtain access to the FTP site.

2Filenames for update files have a UPZ extension and can be obtained from the Downloads page (OPSYS Library) of Crestron’s website.

As of the date of manufacture, this unit has been tested and found to comply with specifications for CE marking.

NOTE: This device complies with part 15 of the FCC rules. Operation is subject to

the following two conditions: (1) this device may not cause harmful interference, and

(2)this device must accept any interference received, including interference that may cause undesired operation.

Cresnet Network Wiring

NOTE: If making category 5 connections to the Cresnet peripherals, refer to the latest revision of the Cresnet Mini Network CAT 5 Interconnect Drawing (Doc. 5819). This document can be obtained from the Downloads page (CABLES and MANUAL Libraries) of Crestron’s website (www.crestron.com). Search for CAT5.PDF. New users are required to register to obtain access to the FTP site.

NOTE: If making modular connections to devices in the Cresnet system, review the latest revision of the Network Modular Cable Requirements (Doc. 5682). This document can be obtained from the Downloads page (CABLES and MANUAL Libraries) of Crestron’s website (www.crestron.com). Search for MODULAR.PDF.

When calculating the wire gauge for a particular Cresnet run, the length of the run and the load factor of each network unit to be connected must be taken into consideration. If Cresnet units are to be daisy-chained on the run, the load factor of each unit to be daisy-chained must be added together to determine the load factor of the entire chain. If the unit is a home-run from a Crestron system power supply

Operations Guide - DOC. 5721

Ethernet/Cresnet Interface: CEN-CN 5

Page 9
Image 9