CyberPower Systems CPS1500AVR Powerpanel Plustm Advanced Setup, Powerpanel Plustm Schedule Menu

Models: CPS1500AVR

1 20
Download 20 pages 7.1 Kb
Page 10
Image 10

6.Delay between warning messages - User adjustable setting for the delay between the audible alarms that occur during a power failure.

7.UPS Self-test- Allows the user to test the UPS without having to unplug the unit from the wall. When the run button is clicked, the unit will switch to battery power and the unit will beep.

8.About - This button will display information about the software, as well as contact information.

9.Advance - This button opens the Advanced Setup Window.

10.Default - Click this button to return the software to the original factory settings.

11.Cancel - This button exits the window without saving changes.

12.OK - This button exits the windows and saves any changes.

13.UPS Installed On - Shows the port that the UPS is using. The port assigned to the UPS needs to

be used exclusively by the PowerPanel PlusTM software.

14.Buzzer - This toggles the audible alarm on and off.

POWERPANEL PLUSTM ADVANCED SETUP

1.Low Battery Voltage - This sets the low battery cutoff level. The user can slightly extend the UPS run-time by adjusting this setting.

2.High-Voltage Failure - Sets the upper level where the UPS will cycle to battery.

3.Low-Voltage Failure - Sets the lower level where the UPS will cycle to battery.

4.Battery-mode Output Voltage - Sets the voltage that the UPS will output when running on battery. This level can be adjusted from 100v to 125v.

5.Cold Start - When enabled, the UPS can start in the absence of AC power. To maximize battery life, it is recommended to keep this disabled.

6.Default - Restores settings to the factory defaults.

7.Cancel - Exits the window without saving changes.

8.OK - Exits the window and saves changes.

9.Remote On Function - This function is not available with this model.

POWERPANEL PLUSTM SCHEDULE MENU

1.Special Setting - This setting allows you to schedule a one-time shutdown/startup.

2.Schedule Display - This area displays the days/dates/times of any scheduled shutdown/startup.

3.Turn On - Select the day/date/time that you want the system to start. Must be scheduled in conjunction with a shutdown.

4.Turn On Disabled - When button states “Turn On Disabled”, the UPS will restart according to the schedule. When button states “Turn On Enabled”, the UPS will not restart according to the schedule.

8

Page 10
Image 10
CyberPower Systems CPS1500AVR user manual Powerpanel Plustm Advanced Setup, Powerpanel Plustm Schedule Menu