CPS1500AVR

Guaranteed Uninterruptible Power System

DESCRIPTION

1.Power Switch

Can be used as a master on/off switch for equipment connected to the UPS.

2.Test Switch

Press this switch to run a self-test.

3.Battery Capacity/ Load Indicator These indicators show a visual indication of the battery charge as well as the unit’s load.

4.Power On Indicator

This LED is illuminated when the utility condition is normal and the UPS outlets are providing power, free of surges and spikes.

5.AVR Indicator

This indicator is illuminated when the unit’s AVR feature is engaged.

6.Using Battery Indicator

This indicator is illuminated when the unit is providing battery power.

7.Wiring Fault Indicator

This LED will illuminate to warn the user that a wiring problem exists within the AC receptacle, such as a bad ground, miss ground or reversed wiring. If illuminated, disconnect all equipment and contact an electrician to insure outlet is properly wired.

9.Battery Backup, Surge Protection and AVR Outlets.

Provides six battery powered, surge protected, AVR outlets for connected equipment and insures temporary

uninterrupted operation of connected equipment during a power failure.

10.Two Serial Ports

Two ports allow connection and communication between the UPS and two computers. This allows the simultaneous shutdown of two computer systems.

11.Communication Protection Ports Ports protect standard modem, fax, telephone line or network cable.

12.10’ Power Cord

Heavy-duty long reach power cord allows you to put power where you need it.

13.Resettable Circuit Breakers Resettable circuit breakers provide optimal overload protection.