CPS1500AVR

Guaranteed Uninterruptible Power System

POWERPANEL PLUSTM MAIN WINDOW DESCRIPTION

1.Input Voltage - This reading shows the current input voltage of the utility power. The input normally displays in green, but will appear in red if the input voltage is lower than 85v of higher than 150v.

2.Battery Level - This indicator displays the current charge on the battery. The indicator will turn red during a power failure.

3.Frequency - This indicator displays the frequency of the utility power.

4.Scheduled On - PowerPanel PlusTM can be scheduled to turn your computer system on. This indicator displays Scheduled on settings that will occur in the next seven days.

5.Final Countdown - When PowerPanel PlusTM detects that the utility voltage is below 85v or above 150v, the final countdown will begin. When the countdown reaches zero, PowerPanel PlusTM will save and close any open files, and then shut down the system in an intelligent and orderly manner.

6.Approximate Backup Time - This indicator shows the approximate amount of backup time that is available, based upon the battery capacity and the load on the system. This indicator can appear in red, yellow, or green, depending upon the number of minutes available.

7.Scheduled Off - PowerPanel PlusTM can be set to automatically shutdown the computer at a user specified time. Scheduled Off settings that are set to occur within seven days are displayed.

8.Temperature - This indicator displays the internal operating temperature of the unit.

9.Load Level - This indicator shows the % of capacity of the battery outlets that is currently being used. This indicator appears in green or gray, but will turn red if the load exceeds 90%.

10.Output Voltage - This indicator shows the output voltage of the UPS.

POWERPANEL PLUSTM SETUP WINDOW

1.Sensitive to variation on Line Voltage - This feature is for other CyberPower Products. The 1500AVR has Automatic Voltage regulation, so this is not needed.

2.Auto-Restart- This feature restores power to the outlets when AC power returns.

3.Software Broadcast - When enabled, the software will play audible voice prompts through your computer speakers.

4.Time Between Power Failure and Shutdown - This is the user controllable

delay between when the power fails and the software starts the shutdown process. If unchecked, the UPS will run until the low battery signal is received (2 minutes of backup time remaining) and then start the shutdown process.

5.Time Between Power Failure and Initial Warning - This setting determines the delay between when the power fails and the first audible alarm.

7

Page 9
Image 9
CyberPower Systems CPS1500AVR user manual Powerpanel Plustm Main Window Description, Powerpanel Plustm Setup Window