CY14B256K

 

 

 

 

 

 

 

Data Retention and Endurance

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

 

Description

Min

 

Unit

DATAR

 

 

Data Retention

20

 

Years

NVC

 

 

Nonvolatile STORE Operations

200

 

K

Capacitance

These parameters are guaranteed but not tested.

Parameter

Description

Test Conditions

Max

Unit

CIN

Input Capacitance

TA = 25°C, f = 1 MHz,

7

pF

 

 

VCC = 0 to 3.0 V

 

 

COUT

Output Capacitance

7

pF

 

Thermal Resistance

These parameters are guaranteed but not tested.

Parameter

Description

Test Conditions

48-SSOP

Unit

ΘJA

Thermal Resistance

Test conditions follow standard test methods and

32.9

°C/W

 

(Junction to Ambient)

procedures for measuring thermal impedance, in

 

 

 

 

accordance with EIA / JESD51.

 

 

ΘJC

Thermal Resistance

25.56

°C/W

 

 

(Junction to Case)

 

 

 

 

 

 

 

 

 

 

Figure 7. AC Test Loads

 

 

R1 577Ω

3.0V

Output

30 pF

R1 577Ω

3.0V

Output

R2

5 pF

 

789Ω

For Tri-state Specs

R2

789Ω

AC Test Conditions

Input Pulse Levels

0 V to 3

V

Input Rise and Fall Times (10% - 90%)

<5 ns

Input and Output Timing Reference Levels

1.5

V

Document Number: 001-06431 Rev. *H

Page 16 of 28