CY7C1292DV18

CY7C1294DV18

TAP AC Switching Characteristics Over the Operating Range[13, 14]

Parameter

Description

Min.

Max.

Unit

tTCYC

TCK Clock Cycle Time

50

 

ns

tTF

TCK Clock Frequency

 

20

MHz

tTH

TCK Clock HIGH

20

 

ns

tTL

TCK Clock LOW

20

 

ns

Set-up Times

 

 

 

 

 

 

 

 

 

tTMSS

TMS Set-up to TCK Clock Rise

5

 

ns

tTDIS

TDI Set-up to TCK Clock Rise

5

 

ns

tCS

Capture Set-up to TCK Rise

5

 

ns

Hold Times

 

 

 

 

tTMSH

TMS Hold after TCK Clock Rise

5

 

ns

tTDIH

TDI Hold after Clock Rise

5

 

ns

tCH

Capture Hold after Clock Rise

5

 

ns

Output Times

 

 

 

 

 

 

 

 

 

tTDOV

TCK Clock LOW to TDO Valid

 

10

ns

tTDOX

TCK Clock LOW to TDO Invalid

0

 

ns

TAP Timing and Test Conditions[13]

 

 

0.9V

 

 

 

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TDO

 

 

 

 

 

 

 

 

 

 

 

Z0 = 50

 

 

 

 

 

 

CL = 20 pF

 

 

0V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALL INPUT PULSES

1.8V

0.9V

tTL

GND

(a)

Test Clock

TCK

Test Mode Select

TMS

Test Data-In

TDI

Test Data-Out

TDO

tTMSS

tTDIS

tTMSH

tTDIH

tTDOV

tTCYC

tTDOX

Notes:

13.Test conditions are specified using the load in TAP AC test conditions. tR/tF = 1 ns.

14.tCS and tCH refer to the set-up and hold time requirements of latching data from the boundary scan register.

Document #: 001-00350 Rev. *A

Page 13 of 23

[+] Feedback

Page 13
Image 13