DC Programming Specifications

Table 24 lists the guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V and -40°C

TA 85°C, 3.0V to 3.6V and -40°C TA 85°C, or 2.4V to 3.0V and -40°C TA 85°C, respectively. Typical parameters apply to 5V, 3.3V, or 2.7V at 25°C and are for design guidance only.

Table 24. DC Programming Specifications

Symbol

Description

Min

Typ

Max

Units

Notes

VddIWRITE

Supply Voltage for Flash Write Operations

2.70

V

 

IDDP

Supply Current During Programming or Verify

5

25

mA

 

VILP

Input Low Voltage During Programming or

0.8

V

 

 

Verify

 

 

 

 

 

VIHP

Input High Voltage During Programming or

2.2

V

 

 

Verify

 

 

 

 

 

IILP

Input Current when Applying Vilp to P1[0] or

0.2

mA

Driving internal pull down resistor.

 

P1[1] During Programming or Verify

 

 

 

 

 

IIHP

Input Current when Applying Vihp to P1[0] or

1.5

mA

Driving internal pull down resistor.

 

P1[1] During Programming or Verify

 

 

 

 

 

VOLV

Output Low Voltage During Programming or

Vss +

V

 

 

Verify

 

 

0.75

 

 

VOHV

Output High Voltage During Programming or

Vdd -

Vdd

V

 

 

Verify

1.0

 

 

 

 

FlashENPB

Flash Endurance (per block)

50,000

Erase/write cycles per block.

FlashENT

Flash Endurance (total)[11]

1,800,

Erase/write cycles.

 

 

000

 

 

 

 

FlashDR

Flash Data Retention

10

Years

 

Note

11.A maximum of 36 x 50,000 block endurance cycles is allowed. This may be balanced between operations on 36x1 blocks of 50,000 maximum cycles each, 36x2 blocks of 25,000 maximum cycles each, or 36x4 blocks of 12,500 maximum cycles each (to limit the total number of cycles to 36x50,000 and that no single block ever sees more than 50,000 cycles). For the full industrial range, the user must employ a temperature sensor user module (FlashTemp) and feed the result to the temperature argument before writing. Refer to the Flash APIs Application Note AN2015 at http://www.cypress.com under Application Notes for more information.

Document Number: 38-12025 Rev. *O