STK17T88

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AutoStore/Power Up RECALL

 

 

 

 

 

 

 

 

 

 

 

 

NO.

Symbols

Parameter

STK17T88

Units

Notes

Standard

Alternate

Min

Max

 

 

 

 

22

tHRECALL

 

 

 

Power up RECALL Duration

 

40

ms

9

23

tSTORE

tHLHZ

STORE Cycle Duration

 

12.5

ms

10, 11

24

VSWITCH

 

 

 

Low Voltage Trigger Level

 

2.65

V

 

25

VCCRISE

 

 

 

VCC Rise Time

150

 

S

 

Figure 9. AutoStore Power Up RECALL

25

2323

22

22

 

NOTE: Read and Write cycles will be ignored during STORE, RECALL and while VCC is below VSWITCH

Notes

9.tHRECALL starts from the time VCC rises above VSWITCH

10.If an SRAM WRITE has not taken place since the last nonvolatile cycle, no STORE will take place

11.Industrial Grade Devices require 15 ms Max.

Document Number: 001-52040 Rev. *A

Page 8 of 22