STK17T88

RTC Register Map

Register

 

 

BCD Format Data

 

 

 

Function / Range

D7

D6

D5

D4

D3

D2

D1

D0

 

 

0x7FFF

 

10s Years

 

 

Years

 

Years: 00-99

0x7FFE

0

0

0

10s

 

Months

 

Months: 01-12

 

 

 

 

Months

 

 

 

 

 

0x7FFD

0

0

10s Day of Month

 

Day of Month

 

Day of Month: 01-31

0x7FFC

0

0

0

0

0

Day of Week

 

Day of week: 01-07

0x7FFB

0

0

10s Hours

 

Hours

 

Hours: 00-23

0x7FFA

0

 

10s Minutes

 

Minutes

 

Minutes: 00-59

0x7FF9

0

10s Seconds

 

Seconds

 

Seconds: 00-59

0x7FF8

OSCEN

0

Cal

 

Calibration [00000]

 

Calibration values*

 

[0]

 

Sign

 

 

 

 

 

 

0x7FF7

WDS

WDW

 

 

WDT

 

 

Watchdog*

0x7FF6

WIE[0]

AIE[0]

PFE[0]

0

H/L [1]

P/L [0]

0

0

Interrupts*

0x7FF5

M

0

10s Alarm Date

 

Alarm Day

 

Alarm, Day of Month: 01-31

0x7FF4

M

0

10s Alarm Hours

 

Alarm Hours

 

Alarm, hours: 00-23

0x7FF3

M

10 Alarm Minutes

 

Alarm Minutes

 

Alarm, minutes: 00-59

0x7FF2

M

10 Alarm Seconds

 

Alarm Seconds

 

Alarm, seconds: 00-59

0x7FF1

 

10s Centuries

 

 

Centuries

 

Centuries: 00-99

0x7FF0

WDF

AF

PF

OSCF

0

CAL[0]

W[0]

R[0]

Flags*

*A binary value, not a BCD value.

0 - Not implemented, reserved for future use.

Default Settings of nonvolatile Calibration and Interrupt registers from factory Calibration Register=00h

Interrupt Register=00h

The User should configure to the desired value at startup or during operation and the value is then retained during a power failure. [ ] designates values shipped from the factory. See Stopping and Starting the RTC Oscillator on page 14.

Document Number: 001-52040 Rev. *A

Page 17 of 22