STK17T88
RTC Register Map
Register | 
  | 
  | BCD Format Data | 
  | 
  | 
  | Function / Range | |||
D7  | D6  | D5  | D4  | D3  | D2  | D1  | D0  | |||
  | 
  | |||||||||
0x7FFF  | 
  | 10s Years  | 
  | 
  | Years  | 
  | Years:   | |||
0x7FFE  | 0  | 0  | 0  | 10s  | 
  | Months  | 
  | Months:   | ||
  | 
  | 
  | 
  | Months  | 
  | 
  | 
  | 
  | 
  | |
0x7FFD  | 0  | 0  | 10s Day of Month  | 
  | Day of Month  | 
  | Day of Month:   | |||
0x7FFC  | 0  | 0  | 0  | 0  | 0  | Day of Week  | 
  | Day of week:   | ||
0x7FFB  | 0  | 0  | 10s Hours  | 
  | Hours  | 
  | Hours:   | |||
0x7FFA  | 0  | 
  | 10s Minutes  | 
  | Minutes  | 
  | Minutes:   | |||
0x7FF9  | 0  | 10s Seconds  | 
  | Seconds  | 
  | Seconds:   | ||||
0x7FF8  | OSCEN | 0  | Cal  | 
  | Calibration [00000]  | 
  | Calibration values*  | |||
  | [0]  | 
  | Sign  | 
  | 
  | 
  | 
  | 
  | 
  | |
0x7FF7  | WDS | WDW | 
  | 
  | WDT | 
  | 
  | Watchdog*  | ||
0x7FF6  | WIE[0]  | AIE[0]  | PFE[0]  | 0  | H/L [1]  | P/L [0]  | 0  | 0  | Interrupts*  | |
0x7FF5  | M  | 0  | 10s Alarm Date  | 
  | Alarm Day  | 
  | Alarm, Day of Month:   | |||
0x7FF4  | M  | 0  | 10s Alarm Hours  | 
  | Alarm Hours  | 
  | Alarm, hours:   | |||
0x7FF3  | M  | 10 Alarm Minutes  | 
  | Alarm Minutes  | 
  | Alarm, minutes:   | ||||
0x7FF2  | M  | 10 Alarm Seconds  | 
  | Alarm Seconds  | 
  | Alarm, seconds:   | ||||
0x7FF1  | 
  | 10s Centuries  | 
  | 
  | Centuries  | 
  | Centuries:   | |||
0x7FF0  | WDF | AF  | PF  | OSCF | 0  | CAL[0]  | W[0]  | R[0]  | Flags*  | |
*A binary value, not a BCD value.
0 - Not implemented, reserved for future use.
Default Settings of nonvolatile Calibration and Interrupt registers from factory Calibration Register=00h
Interrupt Register=00h
The User should configure to the desired value at startup or during operation and the value is then retained during a power failure. [ ] designates values shipped from the factory. See Stopping and Starting the RTC Oscillator on page 14.
Document Number:   | Page 17 of 22  | 
[+] Feedback