Product Data Sheets
Base Grille Water Filtration System (Water Filter)
Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters)
Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; and against ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, Toxaphene,
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % |
Aesthetic Effects | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction |
Chlorine Taste/Odor | ≥50% | 2.1 mg/L | 2.0 mg/L ± 10% | 0.06 mg/L | 0.05 mg/L | 97.1% | 97.6% |
Particulate Class 1* | ≥85% | 5,366,667/mL | At least 10,000 | 4,100/mL** | 2,300/mL | 99.3% | 99.9% |
|
|
| particles/mL |
|
|
|
|
Contaminant | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % |
Reduction | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction |
Lead: @ pH 6.5 | 0.01mg/L | 0.152 mg/L† | 0.15 mg/L ± 10% | 0.001 mg/L | 0.001 mg/L | 99.34% | 99.34% |
Lead: @ pH 8.5 | 0.01mg/L | 0.143 mg/L† | 0.15 mg/L ± 10% | 0.001 mg/L | 0.001 mg/L | 99.30% | 99.30% |
Mercury: @ pH 6.5 | 0.002 mg/L | 0.0061 mg/L | 0.006 mg/L ± 10% | 0.0004 mg/L | 0.0003 mg/L | 93.5% | 96.7% |
Mercury: @ pH 8.5 | 0.002 mg/L | 0.0057 mg/L | 0.0058 mg/L ± 10% | 0.0008 mg/L | 0.00051 mg/L | 85.8% | 91.2% |
Benzene | 0.005 mg/L | 0.0162 mg/L | 0.015 ± 10% | 0.0005 mg/L | 0.001 mg/L | 96.3% | 96.3% |
|
|
|
|
|
|
|
|
0.075 mg/L | 0.220 mg/L | 0.225 ± 10% | 0.0005 mg/L | 0.0005 mg/L | 99.7% | 99.7% | |
Toxaphene | 0.003 mg/L | 0.014 mg/L | 0.015 ± 10% | 0.0014 mg/L | 0.001 mg/L | 90% | 92.96% |
|
|
|
|
|
|
|
|
Atrazine | 0.003 mg/L | 0.0086 mg/L | 0.009 mg/L ± 10% | 0.0005 mg/L | 0.0005 mg/L | 94.25% | 94.25% |
|
|
|
|
|
|
|
|
2, | 0.07 mg/L | 0.197 mg/L | 0.210 ± 10% | 0.058 mg/L | 0.0137 mg/L | 70.6% | 93.06% |
Asbestos | 99% | 26 x 107 | 107 to 108 fibers/L†† | 0.18 x 107 mg/L | 0.18 x 107 mg/L | 99.93% | 99.93% |
|
|
|
|
|
|
|
|
Cysts‡ | 99.95% | 111,000/mL | 50,000/L min. | 1 mg/L | 1 mg/L | 99.99% | 99.99% |
Turbidity | 0.5 NTU | 11.00 NTU | 11 ± 1 NTU | 0.40 NTU | 0.35 NTU | 96.4% | 96.8% |
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F (17.2°C).
It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
Model
The product is for cold water use only.
Application Guidelines/Water Supply Parameters
Water Supply | City or Well |
Water Pressure | 30 - 120 psi (207 - 827 kPa) |
Water Temperature | 33° - 100°F (0.6° - 37.8°C) |
Service Flow Rate | 0.5 GPM (1.89 L/min.) @ 60 psi. |
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
†These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. †† Fibers greater than 10 um in length
‡ Based on the use of Cryptosporidium parvum oocysts ® NSF is a registered trademark of NSF International.
18