4-9. Compensation of R-sensor ON/OFF Point

INPUT

CONTROL OBJECT

Main PCB

Resistance of R-sensor Mid ON/OFF Point

CONTENTS

REMARKS

 

 

Compensation of R-sensor ON/OFF temp. (down)

In case temperature of refrigerator compartment is weak or insufficient, take the following action.

FRS(N)-U20IA

FRS(N)-U20DA

 

 

 

R-SENSOR

 

 

R-SENSOR

Refer to the 5-2.

 

 

 

 

 

 

 

 

 

(Function of each sensor)

R36

 

 

R36

 

 

R37

 

 

R37

 

 

R38

J2

J1

R38

J19

J18

J1

J18,19

J2

R36 : R-SENSOR standard resistance in normal mode (31.4K)

R37 : In case of weak ref., cut J1 (or J18) to down the standard resistance by 1.5deg(2K)

R38 : In case of weak ref., cut J2 (or J19) to down the standard resistance by 1.5deg(2K)

FRS(N)

J1

-

cut

cut

J2

-

-

cut

-U20IA

Temperature

0

-1.5

3

 

compensation

 

 

 

 

FRS(N)

J18

-

cut

cut

J19

-

-

cut

-U20DA

Temperature

0

-1.5

3

 

compensation

 

 

 

 