CONTENTS

REMARKS

 

 

9) “EI”ERROR

Cause : I-SENSOR disconnection / short

Check point : Measure the resistance between both terminals after separating CN11 of the Main PCB. (Refer to the 5-2.)

If F-sensor is disconnected or shorted , change the I-sensor in the automatic ice maker.

10) “EF” ERROR

Cause : When Flow-sensor ERROR (There is no Pulse during some time) The number of pulse signal is below 10 by 1 sec during water supply.

Check point : Water supply line

11) “Eg” ERROR

Cause : I-sensor temp (5min after water supply) doesn’t go up. Check the I-sensor or water supply line.

12) “ES” error (MICRO switch error)

Cause : When it senses 1min continuously Check the MICRO switch of the dispenser.

13) “Ea” error

Cause : Malfunction of ice drop motor. Check the motor by pushing test switch.

14) “Eu” error

Cause : Switch (which senses if the ice is full or not) is in error.

Control : When dropping the ice, the motor just rotates 90 degree.

Termination : When the switch is in normal.

15)“EA“ ERROR

Cause : When sensing Ice dropping by time 3 times in level sensor SW Error.

Control : Stop of Ice Maker

Termination : With normal level switch.

Re-input of power or push if icemaker test switch.

16)“Et” ERROR

Cause : Level switch error (No pulse is sensed for some time)

Control : By time (Supply mode is skipped)

Termination : Normal condition.

* When all ERROR CODE is normal, the Refrigerator reset

24

Page 25
Image 25
Daewoo frs20 manual Eierror