EXHAUST SYSTEMS (GENERAL)

PELLET VENT MUST MAINTAIN A MINIMUM 3” CLEARANCE TO ANY COMBUSTIBLE

(INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER).

DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE

OR STOVE.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

PELLET VENT TYPE:

Must be an approved 3” or 4” Diameter Type ”PL” vent, vented to the outside (fig. 7) or connect the vent to a factory built type “A” chimney using an adaptor; and/or “All Fuel” Stainless Steel chimney liner for masonry fireplace installations (fig. 8) . Use 4” dia. vent if vent or liner height is over 15’ or if installation is over 4,000’ above sea level.

VENTING DISTANCE:

Maximum venting height is 33’. Maximum horizontal offset is 10’. Use no more than 180 of elbows (two 90 elbows, or two 45 elbows

&one 90 elbow, etc), plus termination.

Vent must have a support

 

 

 

 

 

Use 4” Diameter “PL” Vent

bracket every 5’ when on

the exterior wall.

If venting outside of

 

 

shaded area.

 

 

 

 

 

 

 

 

 

 

 

 

If appliance is installed

 

 

above 4,000’ elevation,

Use 3” or 4” Diameter

 

always use 4” diameter

“PL” Vent, if venting in

 

venting.

shaded area.

 

Vent height and run must

 

 

not exceed the distance

 

 

shown in the un-shaded

 

 

region of chart.

 

 

To achieve optimum

 

 

performance, keep vent runs

 

 

as short as possible.

 

 

Especially on horizontal

 

 

installations.

 

 

0’

5’

10’

VENT INSTALLATION:

33’

30’

25’

20’

15’

10’

5’

0’

Termination must exhaust above the air inlet elevation, and parallel or above the exhaust output of the pellet appliance. It is recommended that at least 3’ of vertical pipe be installed to create some natural draft. This is to help prevent the possibility of smoke or odor during the appliance shut down.

Horizontal sections must have a ¼” rise every 12” of travel after 3’ long.

Pellet Vent connections must be sealed with HI-Temp RTV Silicone and screwed together with at least 3 x 3/8” long stainless steel screws. Seal each vent section by injecting a liberal amount of HI- TEMP RTV silicone sealant into the gap.