Dansons Group HCJ, HCF120, HCS, HCF300 manual THROUGH THE WALL - DIRECT INSTALLATION. Figure, B H G C

Models: HCJ HCF300 HCS HCF120

1 39
Download 39 pages 26.02 Kb
Page 15
Image 15
THROUGH THE WALL - DIRECT INSTALLATION. (Figure 18)

FREESTANDING INSTALLATION . . . continued

THROUGH THE WALL - DIRECT INSTALLATION. (Figure 18)

1.Select the location for your stove, design the exhaust system and determine the brand and size of "PL" vent to be used.

2.Position the floor pad. (C).

3.INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER

Following the "PL" vent manufacturer's specifications, mark and cut a hole through the wall to accommodate the wall thimble, (A), and the outside air pipe, (B), if outside air is to be used.

Install the wall thimble, (A). Be sure to run a bead of silicone around the outside edges of the wall thimble to reduce drafts. Insert the proper size of "PL" vent, (D), through the wall thimble,

(A).

Place your stove on the floor pad, (C), close to its final position. Leave room to connect the "PL" vent to your stove. Place a bead of RTV silicone around the end of your stove's exhaust pipe, (E). Connect the “PL” vent pipe adaptor (J) onto the stoves exhaust pipe.

Connect the length of "PL" vent, (D), that is in the thimble, (A), onto the pipe adaptor (E). Fasten together with at least three sheet metal screws (approx. ½” in length). Place a bead of RTV silicone around the connection.

Place your stove in its final position on the pad. Place another bead of RTV silicone around the “PL” vent and the inside of the wall thimble, to stop cold air drafts.

Note: If 4" PL vent is required, use an increaser, (J), on the stove exhaust pipe.

4.On the outside of the building, place a 45 degree "PL" type elbow, (F), onto the end of the horizontal "PL" vent, (D). Optionally, place a rodent screen cap, (G), (may be required in some locals), on the end of the elbow, (F). Secure all connections using 3 sheet metal screws and run a bead of RTV silicone around all connections. Also run a bead of RTV silicone around the “PL” vent pipe and the outside of the wall thimble.

5.If outside air is used, install the outside air pipe, (B). Seal the outside air pipe, (B), to your stove's outside air pipe, (I), with RTV silicone. Make sure the outside air pipe fits over, (not inside), your stove's outside air pipe. Install a wind shield (H). Run a bead of silicone around the inside and outside walls, again to reduce cold drafts.

12”

1”

1”

10”  B H G C 10”Manual backgroundManual background

6”

6”

A

PL Wall Thimble

B

Outside Air Intake

C

Hearth Pad

D

PL Vent Length

E

Stove Exhaust

F

PL 45 deg elbow

G

PL Screened End Cap

H

Outside Air Intake Screen

 

Cap

I

Combustion Air Intake

J

PL Pipe Adaptor

Manual backgroundManual backgroundManual backgroundManual backgroundEJ AManual backgroundManual backgroundManual background AManual backgroundD Manual backgroundF

Manual background B H G C

Figure 18

NOTE: Some horizontal, through the wall installations may require a Clean-Out Tee and a minimum 3’ vertical rise of pipe outside the building to help draft the stove. This is required if a proper burn cannot be maintained, after the stove has been tested and the airflow set. This is due to backpressure in the exhaust, caused by the airflow around the house.

Copyright 2004

15

Cheap Charlie Owner’s Manual

Canadian Comfort Industries

www.dansons.com

Dansons Group Inc.

Page 15
Image 15
Dansons Group HCJ, HCS THROUGH THE WALL - DIRECT INSTALLATION. Figure, B H G C, FREESTANDING INSTALLATION . . . continued