INITIAL APPLIANCE BURN SETUP

IT IS CRITICAL FOR THE CORRECT OPERATION OF YOUR STOVE THAT THE BURN

GRATE, AIR INLET DAMPER, COMBUSTION FAN SPEED, AND

1 & 4 FUEL RATE BE SET CORRECTLY!

A HIGH QUALITY FIRE should burn with a brisk, yellow flame. A flame exhibiting a lazy, orange or sooty characteristic is a poor quality and inefficient flame. A poor flame produces less heat, increases sooting and may cause a smoky exhaust. If a poor flame exists for any period of time, clean your stove and exhaust system.

Note: if log option is purchased, do not install until initial setup is complete

FEED RATE

4

3

2

1

START

FEED RATE

START APPLIANCE AS PER LIGHTING INSTRUCTIONS,

let stove run for approx. 10 minutes before turning the stove to the # 4 setting (or High), to begin to make fine adjustments. AUGER CYCLE indicator should be lit “ON” for 3 seconds and “OFF” for 3-5 seconds. Adjust the AIR INLET DAMPER. This will have to be set, as the factory sends all units out with the damper wide open to accommodate a wide range of installations and elevations.

AIR INLET DAMPER: Slide open or close

 

 

 

 

damper as needed to obtain a fire that is brisk

 

 

Air Inlet

enough to carry ash out of the grate, but not so

 

 

 

 

Slide Rod

brisk that it carries pellets out as well (known as

 

 

 

 

“Pop corning”). Normally you should find that the

 

 

 

 

damper will need to be closed two-thirds to three

 

Rubber

quarters, but will vary with length of vent run, pellet

Stove Back Panel

GrometT

quality and elevation. The best way to set this is at

 

 

 

 

 

the FUEL SETTING #4.

 

Right Hand

 

 

Side Panel

FEED RATE

When you are pleased with the burn and how the appliance is operating, you

are now ready to set the board up at LOW setting.

 

 

4

 

 

Set FUEL RATE to #1 or LOW setting. Again let this burn for

 

 

 

approx. 10 minutes before making any adjustments. The AUGER

Decrease

Increase

3

CYCLE indicator should be “OFF” for approx 9 – 14 seconds

between auger turnings (light ON). If “Pop corning” is taking place

FINE TUNE ADJUSTMENTS

 

at this setting adjust the COMBUSTION FAN SPEED.

 

 

2

COMBUSTION FAN SPEED (Draft): In a few instances

 

 

 

because of prevailing conditions pertinent to your specific

1

4

1

installation, or even different batches of pellet fuel, the

COMBUSTION FAN SPEED may be adjusted to increase or

 

 

 

decrease the amount of air moving through the grate for the

 

FAN

 

cleanest burn. Fan speed can be adjusted by adjusting the FAN

 

START

 

 

trim pod COUNTER CLOCKWISE to INCREASE the speed and

 

 

FEED RATE

CLOCKWISE to DECREASE the speed of the combustion fan.

 

 

 

 

 

FUEL RATE: Fuel rate at the Lowest (number 1) and highest (number 4) settings can be changed by adjusting the #1 or #4 TRIM PODS located on the control panel. To INCREASE fuel rate turn trimmer COUNTER CLOCKWISE and to LOWER turn CLOCKWISE. To assist in knowing what changes you made, you should note the amount of time the light on the AUGER CYCLE stays “OFF”. (Note: The light stays “off” when ever the fuel feed motor is not running). Lengthening the time this light stays “OFF” lowers the fuel feed and shortening the “OFF” time increases the fuel feed. Factory Setting #1 light “OFF” is approx. 9-11 seconds, #4 light “OFF” is 3-4 seconds.

Canadian Comfort Industries V04

28

PELPRO OWNERS MANUAL

Copyright 2004

www.pelprostoves.com

Dansons Group Inc.

Page 28
Image 28
Dansons Group IPP, FPP, FPP, IPP, FPP Freestanding, IPP Bay View Insert / Built-In manual Initial Appliance Burn Setup, Start

IPP Bay View Insert / Built-In, FPP, IPP, FPP Freestanding, IPP, FPP specifications

Dansons Group is renowned for its innovative approach to outdoor and indoor heating solutions, especially with their FPP Freestanding and IPP Bay View Insert/Built-In models. These products are designed to cater to the diverse needs of homeowners seeking both functionality and aesthetics in their heating appliances.

The FPP Freestanding model is a perfect blend of traditional charm and modern technology. It serves as an impressive centerpiece in any setting, providing warmth and ambiance to any space. One of its standout features is its large viewing area, which allows for an unobstructed view of the flames, creating a cozy and inviting atmosphere. It is equipped with advanced combustion technology that ensures efficient burning, maximizing heat output while minimizing emissions. This model is also designed to accommodate a range of fuel options, including wood and pellets, giving users the flexibility to choose what works best for them.

On the other hand, the IPP Bay View Insert/Built-In model offers a seamless integration into existing fireplaces or as a built-in feature in new constructions. This model emphasizes both performance and aesthetics, providing a sleek finish that enhances any room's decor. One of the key technologies in the IPP is its advanced blowers and distribution system, which efficiently circulates heat throughout the space, ensuring even warmth without hot spots. Additionally, the IPP incorporates a unique air-wash system that keeps the glass clean, allowing for a clear view of the flickering flames.

Both the FPP and IPP series prioritize ease of use and maintenance. They are designed with user-friendly controls that allow for easy operation and customization of heat settings. Moreover, Dansons Group emphasizes safety, incorporating features such as automatic shut-off mechanisms and cool-touch exteriors to prevent accidental burns.

In summary, the Dansons Group FPP Freestanding and IPP Bay View Insert/Built-In models stand out for their combination of aesthetic appeal, technological advancement, and user-friendly features. Whether you're looking for a statement piece or a practical heating solution, these products are designed to create a warm ambiance while ensuring efficiency and safety.