INSTALLATION

2

 

C-BOX pinout for Matrix-1000™

The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the Matrix-1000™ reader is connected by means of the C-BOX 100:

 

 

C-BOX 100 Terminal Block Connectors

 

 

 

 

 

Power

1, 3, 5

VS

2, 4, 6

GND

7,

8

EARTH GROUND

20,

40

Reserved

 

 

Inputs

27

EXT TRIG A (polarity insensitive)

28

EXT TRIG B (polarity insensitive)

29,

30

NC

31,

33

NC

32,

34

NC

36

NC

 

 

Outputs

21,

22

NC

23,

24

NC

25

OUT 3+

26

OUT 3-

 

 

Auxiliary Interface

35

TX AUX

37

RX AUX

38,

39

GND

 

 

Main Interface

 

 

RS485 Half-Duplex

11,

15

RTX485+

12,

16

RTX485-

17

NC

18

NC

10, 14, 19

SGND

9, 13

RS485 Cable Shield