SOFTWARE CONFIGURATION

3

 

3.4CONFIGURATION

Once connected to Matrix-1000as described in par. 3.3, you can modify the configuration parameters as follows:

1.Press the Calibration Tool button from the Main Menu. Matrix-1000™ will download its permanent memory configuration parameters with the default values (if it is the first time) to VisiSet™. The Calibration Tool window will be displayed together with the Parameter Setup window working in Interactive Mode (see par. 3.4.1 and par. 3.4.2).

2.Edit the Matrix-1000configuration parameters according to your application requirements.

3.Use the Calibration Tool to fine tune the reading performance. See par. 3.4.2.

4.Close the Calibration Tool window and disable the Interactive Mode by pressing the interactive button.

5.Save the new configuration to the reader permanent memory by pressing the Send button.

6.Close the Parameter Setup window and press Disconnect on the VisiSet™ menu bar (see Figure 28) or launch Run Mode from the VisiSet™ Main menu.

Disconnect exits closing communication between Matrix-1000and VisiSet™, and causes Matrix-1000to enter Run Mode. The disconnected reader serial port is now available for other purpose.

Run command does not close communication between Matrix-1000and VisiSet™, and causes Matrix-1000to enter Run Mode. In this case the reader output messages are displayed on the VisiSet™ terminal and the statistics are displayed in the Statistics window (Statistics enabled).

31