INSTALLATION | 2 |
|
An
2.3.5Outputs
One optocoupled general purpose output is available on the
Pin | Name | Function |
|
16 | OUT3+ | Configurable digital output 3 | - positive pin |
17 | OUT3- | Configurable digital output 3 | - negative pin |
It is typically used to signal the data collection result. It can also be used to control an external lighting system
The idle state, the activation/deactivation events and the other configuration parameters can be defined by the user. Refer to the Digital I/O folder in the VisiSet™ Help On Line for further details.
MATRIX | USER INTERFACE |
| Vext 30 Vdc max |
+ |
|
V Out | I Load |
- |
|
Figure 21 - Open Collector Output Connection
The electrical features of the output are the following:
| OUTPUT |
| ILoad | VOut |
| Open |
| 0 mA | 30 Vdc Max |
| Closed |
| 10 mA | 1.8 Vdc Max |
PD = VOut ⋅ | IoLoad = 170 mW Max. |
|
21