54

 

 

 

Matrix-1000™

 

 

 

 

 

 

 

 

 

 

TROUBLESHOOTING GUIDE

Problem

 

 

Suggestion

 

 

One Shot or Phase Mode

In the Operating Mode folder check the settings

using

serial

trigger

for Phase-ON, Acquisition Trigger and

source:

 

 

Phase-OFFparameters.

no image is displayed in

Are the COM port parameters (Baud Rate,

Visiset™

Calibration Tool

Parity, Data Bits, Stop Bits, Handshake)

window while your

trigger

correctly assigned?

source is transmitted on the

In the communication folder, check the settings

reader serial port.

 

of Phase-ON String, Acquisition Trigger

 

 

 

String and Phase-OFF String parameters.

 

 

 

Is the serial trigger source correctly connected?

Phase Mode:

 

In

the Operating Mode folder check the

no result is transmitted by

Phase-OFFparameter setting.

the reader at the end of the

In the Data Collection folder check the settings

phase collection.

 

for the COLLECTION, DATA FORMAT and

 

 

 

STATISTICS parameter groups.

 

 

 

 

Reading:

 

 

Position the reader as described in par. 2.5 and

the reader always transmits

through the VisiSet™ Calibration Tool:

the No-Read Message

-

Tune the DELAYED TRIGGERS, if the

 

 

 

 

moving code is out of the reader field of

 

 

 

 

view;

 

 

 

-

Set the Continuous Operating Mode if no

 

 

 

 

external trigger source is available;

 

 

 

-

Tune the ACQUISITION RECIPE to

 

 

 

 

improve the code image quality;

 

 

 

-

Check the parameter setting in Decoding,

 

 

 

 

2DCodes, 1Dcodes, and Postal Codes

 

 

 

 

folders;

 

 

 

-

View the full resolution code image to

 

 

 

 

check the printing or marking quality.

Communication:

 

Is the serial cable wiring correct?

reader is

not transmitting

Are the host serial port settings the same as the

anything to the host.

 

reader serial port settings?

Communication:

 

Are the host serial port settings the same as the

data transferred to the host

reader serial port settings?

are incorrect, corrupted or

In VisiSetCommunication folder check the

incomplete.

 

settings of Header and Terminator parameters.

 

 

 

In VisiSet™ Data Collection folder, check the

 

 

 

settings of DATA FORMAT parameter group.

44