Datamax 7A300007 Rev. 2 Printer Controls Data Processing, Enable Buffer Mode, Esc P $, Esc P #

Models: 7A300007 Rev. 2

1 67
Download 67 pages 48.07 Kb
Page 32
Image 32

This data may be represented in hexadecimal:

0x55

0x55

0x00

0x00

0xAA

0x11

 

 

 

 

 

 

0x55

0x00

0x55

0x55

0x55

0x55

 

 

 

 

 

 

The RLE compressed graphics command:

 

ESC

‘v’

height

width

counter

data…

 

 

 

 

 

 

 

 

 

DEC

27

118

2

6

255

85

255

0

3

170

17

85

0

253

85

HEX

0x1B

0x76

0x02

0x06

0xFF

0x55

0xFF 0x00 0x03

0xAA

0x11

0x55

0x00

0xFD

0x55

Printer Controls – Data Processing

The printer can be operated in two modes, Online and Buffer mode. In online mode, the characters are printed as they are received. In buffer mode, the characters received are stored in the print buffer and printed upon receipt of the EOT character (^D). Also if the printer is in Buffer Mode and the print buffer is full, the printer will start printing but will remain in the Buffer Mode until the Online Mode command is sent to the printer.

Enable Buffer Mode

ESC P $

This command selects the printer buffer mode.

Escape Sequence:

ESC

P

$

 

Hexadecimal:

1B

50

24

 

Decimal:

27

80

36

 

Disable Buffer Mode (Select Online Mode)

ESC P #

This command disables the printer buffer mode and selects the online mode. The online mode is the default mode of operation of the printer.

Escape Sequence:

ESC

P

#

Hexadecimal:

1B

50

23

Decimal:

27

80

35

26

Page 32
Image 32
Datamax 7A300007 Rev. 2 manual Printer Controls Data Processing, Enable Buffer Mode, Esc P $, Esc P #