Datamax 7A300007 Rev. 2 manual Communications Settings, Dip Switch Settings, Off, OFF 2USB

Models: 7A300007 Rev. 2

1 67
Download 67 pages 48.07 Kb
Page 58
Image 58

Communications Settings

Dip Switch Settings

The Datamax-O’Neil printers support Serial RS232, IrDA compatible infrared communication interfaces and USB*1.Bluetoothand Wi-Fi communication are also available as an optional feature. Serial/USB IrDA, Wi-Fi and Bluetoothcommunication settings can be changed via a DIP switch located on the control card. In the following sections each setting is discussed in more detail.

Function (APEX2,3,4)

 

 

 

 

 

 

 

Switch #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Communication Interface

 

 

SW 1

 

SW 2

 

SW 3

 

SW 4

 

SW 5

 

SW 6

 

SW 7

 

SW 8

RS232

 

OFF

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1IrDA

 

ON

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bluetooth or 802.11g

 

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

 

N/A

 

ON

 

ON

 

 

 

 

 

 

 

 

 

 

 

2USB

 

X

 

X

 

 

 

 

OFF

 

OFF

 

ON

 

3USB Bootloader

 

X

 

X

 

 

 

 

ON

 

OFF

 

ON

 

4Baud Rate

 

 

 

 

 

 

SW 3

 

SW 4

 

SW 5

 

 

 

 

 

 

115200

 

 

 

 

 

 

OFF

 

OFF

 

OFF

 

 

 

 

 

 

57600

 

 

 

 

 

 

ON

 

OFF

 

OFF

 

 

 

 

 

 

38400

 

 

 

 

 

 

OFF

 

ON

 

OFF

 

 

 

 

 

 

19200

 

 

 

 

 

 

ON

 

ON

 

OFF

 

 

 

 

 

 

14400

 

 

 

 

 

 

OFF

 

OFF

 

ON

 

 

 

 

 

 

9600

 

 

 

 

 

 

ON

 

OFF

 

ON

 

 

 

 

 

 

2400

 

 

 

 

 

 

OFF

 

ON

 

ON

 

 

 

 

 

 

1200

 

 

 

 

 

 

ON

 

ON

 

ON

 

 

 

 

 

 

Parity Bit

 

 

 

 

 

 

 

 

 

 

 

 

SW 6

 

SW 7

 

 

Parity Enabled (ODD)

 

 

 

 

 

 

 

 

 

 

 

ON

 

ON

 

Parity Enabled (EVEN)

 

 

 

 

 

 

 

 

 

 

 

ON

 

OFF

 

Auto Power Save

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW 8

Power Save Enabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

Power Save Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Notes

Baud rate set by Dip switches 3,4

and 5

Baud Rate can be negotiated up to

the value specified through Dip

switches 3,4 and 5

Setting not supported

RS232 and IrDA only

Use for fixed IrDA

Does not apply for IrDA

Does not apply for IrDA

Auto Power Down

Manual On/Off

1If IrDA is not installed, printer will default to RS232 mode with baud rate 115200

2X stands for Don’t Care: Dip Switch 7 will override 1 and 2

3Firmware Applies to Apex 4 - Version 1.10 or later, Check availability for other printer models

4Baud Rate and Parity are applicable to RS232 and IrDA communication mode ONLY