RS232C Technical Specifications

Name

Value

 

 

Data Transfer Rate

1200 – 115200 Baud

 

 

Word Length

10 or 11 bits

Start Bit

1

Data Bits

8

Parity Bit

None, Odd or Even

 

 

Stop Bits

Auto Select 1 or 2

Signal Levels

RS232C

 

 

Mark or Logical 1

-3 to -15 VDC

Space or Logical 0

+ 3 to + 15 VDC

Handshaking

Two modes are supported (Software and Hardware)

Hardware

RTS/CTS

Software

XON/XOFF

Auto Power Up

Positive Signal on RTS input switches the printer ON

USB Communication (USB)

Overview

Apex printer comes equipped with a USB 2.0 slave port. Everything that can be done through the RS-232 port can now be done through the USB port, using A to B type USB cable. You may print to or send commands to the printer from a PC or any equipment that can act as a USB master.

Dip switch setting

To enable USB, you must set the dipswitches on the printer as below:

SW 1

SW 2

SW 3

SW 4

SW 5

SW 6

SW 7

SW 8

Any

Any

Any

Any

Any

Off

On

Any

position

position

position

position

position

 

 

position

Compatible Software

The host and printer communicate through a method called the "Virtual Com Port", in which a software intermediary called the "driver" makes the USB connection look like a com port to the end-application. Consequently, all software that communicates through the com port is compatible. You may continue to use legacy software, such as the TeraTerm terminal emulation software.