Datamax 7A300007 Rev. 2 manual Bluetooth & WiFi Setup Command

Models: 7A300007 Rev. 2

1 67
Download 67 pages 48.07 Kb
Page 55
Image 55

Bluetooth™ & WiFi Setup Command

Datamax-O’Neil printers can be placed in pass-thru mode. In pass-thru mode, data communication will only occur between the two selected UARTS. This mode of operation is used to setup the Bluetoothor 802.11b/g interface parameters. While in this mode, printing is disabled.

Select Pass-Thru Command Mode

ESC P U n1 U n2 T t0 t1 t2 (CR)

This command sets the printer in pass-thru mode. In most serial applications the command can be sent manually or as a file. For UART selection only use ECU application.

Parameter

Description

 

 

n1

Source UART, values 0 – 4

 

UART0 = Serial Interface

 

UART1 = Wireless Interface (BT, WiFi)

 

UART2 = Wireless Interface (BT, WiFi)

 

UART3 = IrDA Interface

 

UART4 = USB Interface

n2

Destination UART, values 0 – 4

 

UART0 = Serial Interface

 

UART1 = Wireless Interface (BT, WiFi)

 

UART2 = Wireless Interface (BT, WiFi)

 

UART3 = IrDA Interface

 

UART4 = USB Interface

t0

Pass-thru timeout, value 0 – 9

t1

Pass-thru timeout, value 0 – 9

t2

Pass-thru timeout, value 0 – 9

Note: Pass-thru timeout value 000 is not a valid entry

Example 1: The Pass-thru sequence below is used to put Apex2 printer is Pass-thru mode from serial to Wireless with timeout value set to 999 seconds.

Escape Sequence:

ESC

P

U

0

U

2

T

9

9

9

CR

Hexadecimal:

1B

50

55

00

55

32

54

09

09

09

0D

Decimal:

27

80

85

0

85

50

84

9

9

9

13

Example 2: The Pass-thru sequence below is used to put Apex3 printer is Pass-thru mode from serial to Wireless with timeout value set to 999 seconds.

Escape Sequence:

ESC

P

U

0

U

1

T

9

9

9

CR

Hexadecimal:

1B

50

5

00

55

31

54

09

09

09

0D

Decimal:

27

80

85

0

85

49

84

9

9

9

13

Example 3: The Pass-thru sequence below is used to put Apex4 printer is Pass-thru mode from USB to Wireless with timeout value set to 999 seconds.

Escape Sequence:

ESC

U

4

U

2

T

9

9

9

CR

Hexadecimal:

1B

50

55

55

32

54

09

09

09

0D

Decimal:

27

80

85

85

50

84

9

9

9

13

Note: Pass-thru command is not available when Source (n1) = Destination (n2)

The Pass-thru mode terminates under three conditions:

After pressing the FEED button

After TIMEOUT duration specified in the pass-thru command has EXPIRED

After receiving three consecutive “#” characters.