Dayton specifications Storing Generator, Dayton Generator, 2ZRP8, 2ZRP9, SHORT TERM 1-6months

Models: 2ZRP8 2ZRP9

1 80
Download 80 pages 27.22 Kb
Page 10
Image 10
Storing Generator

Dayton Operating Instructions and Parts Manual

2ZRP8, 2ZRP9

Dayton® Generator

E

 

 

 

Spark Plug Gap

N

 

(See recommendations)

G

 

 

L

 

 

I

 

 

S

 

 

H

 

 

 

 

 

 

 

 

must comply with fire prevention regulations.

Clean the spark arrester as follows:

1.Loosen the screw by the exhaust port of the muffler and remove the spark arrester.

2.Use a brush to remove carbon deposits from the spark arrester screen. Inspect the screen for breaks or tears and replace it if necessary.

3.Install the spark arrester in the reverse order of removal.

Spark arrestors are available from your local Dayton Customer Service Representative. Other user lrequirements may apply, check with your Federal, State or local authorities.

Storing Generator

SHORT TERM (1-6 months):

1.Add gasoline conditioner and stabilizer at the specified concentration.

2.Run the unit for two (2) minutes to ensure the mixed fuel is in the entire fuel system. Close the fuel valve and run the unit until it stops.

3.Remove the spark plug, pour 1-2 teaspoons (5-10cc) of engine oil into the cylinder, slowly pull the starter handle 2 or 3 times, reinstall the spark plug and tighten securely.

4.Clean the exterior surface of the generator and apply a rust inhibitor.

5.Store the generator in a dry, well ventilated place.

LONG TERM (More than 6 months):

1.Add gasoline conditioner and stabilizer at the specified concentration.

2.Run the generator until the fuel tank and carburetor are dry. As the engine is beginning to die, move the choke lever to the choke position.

NOTE: Turn off the idle control to decrease the run time.

3.Remove the spark plug, pour 1-2 teaspoons (5-10cc) of engine oil into the cylinder, slowly pull the starter handle 2 or 3 times, reinstall the spark plug and tighten securely.

4.Clean the exterior surface of the generator and apply a rust inhibitor.

5.Store the generator in a dry, well ventilated place.

FUEL SHOULD BE DRAINED IN A WELL

VENTILATED AREA AND STORED IN A CONTAINER APPROVED FOR GASOLINE.

10

Page 10
Image 10
Dayton Storing Generator, Dayton Generator, 2ZRP8, 2ZRP9, SHORT TERM 1-6months, LONG TERM More than 6 months