Table 1-4. LED Status

LED

Color

Status

Occurrence

Note

 

 

 

 

 

ID LED

Blue

Off

Normal status (by IPMI

Turn off the ID LED.

 

 

 

Chassis Identify

1. ipmitool raw 0x00 0x04

 

 

 

command or System ID

0x00

 

 

 

Button)

2. ipmitool raw 0x00 0x04

 

 

 

 

0x00 0x00

 

 

Solid On

Identify the system

Turn on the ID LED.

 

 

 

 

1.ipmitool raw 0x00 0x04 0x3c

 

 

 

 

01

 

 

Blinking

Identify the system with

1. IPMI chassis identify

 

 

 

interval

command without request

 

 

 

 

data ipmitool raw 0x00 0x04

 

 

 

 

2. IPMI chassis identify

 

 

 

 

command with only 1

 

 

 

 

parameter data ipmitool raw

 

 

 

 

0x00 0x04 0x3c (blink 60 sec)

 

 

 

 

3. IPMI chassis identify

 

 

 

 

command with 2 parameter

 

 

 

 

data ipmitool raw 0x00 0x04

 

 

 

 

0x3c 0x00 (blink 60 sec)

Heartbeat

Green

Off

BMC is not ready

 

LED

 

Blinking

BMC is ready

 

 

 

 

 

 

Table 1-5. Blinking Fault LED Conditions

 

Index

Sensor Name

Event Triggers

 

 

 

 

1

CPU Temp

• Upper Critical Going High

 

Ambient Temp,

• Upper Non-Critical Going High

 

DIMM Temp

 

 

 

Rear Temp 1

 

 

 

Rear Temp 2

 

 

 

Rear Temp 3

 

 

2

SLED 12V

 

• Upper Critical Going High

 

 

 

• Upper Non-Critical Going High

14

Page 14
Image 14
Dell C5220 manual Led, Sled