Table
LED | Color | Status | Occurrence | Note |
|
|
|
|
|
ID LED | Blue | Off | Normal status (by IPMI | Turn off the ID LED. |
|
|
| Chassis Identify | 1. ipmitool raw 0x00 0x04 |
|
|
| command or System ID | 0x00 |
|
|
| Button) | 2. ipmitool raw 0x00 0x04 |
|
|
|
| 0x00 0x00 |
|
| Solid On | Identify the system | Turn on the ID LED. |
|
|
|
| 1.ipmitool raw 0x00 0x04 0x3c |
|
|
|
| 01 |
|
| Blinking | Identify the system with | 1. IPMI chassis identify |
|
|
| interval | command without request |
|
|
|
| data ipmitool raw 0x00 0x04 |
|
|
|
| 2. IPMI chassis identify |
|
|
|
| command with only 1 |
|
|
|
| parameter data ipmitool raw |
|
|
|
| 0x00 0x04 0x3c (blink 60 sec) |
|
|
|
| 3. IPMI chassis identify |
|
|
|
| command with 2 parameter |
|
|
|
| data ipmitool raw 0x00 0x04 |
|
|
|
| 0x3c 0x00 (blink 60 sec) |
Heartbeat | Green | Off | BMC is not ready |
|
LED |
| Blinking | BMC is ready |
|
|
|
| ||
|
| |||
Table |
| |||
Index | Sensor Name | Event Triggers |
| |
|
|
| ||
1 | CPU Temp | • Upper Critical Going High | ||
| Ambient Temp, | • Upper | ||
| DIMM Temp |
|
| |
| Rear Temp 1 |
|
| |
| Rear Temp 2 |
|
| |
| Rear Temp 3 |
|
| |
2 | SLED 12V |
| • Upper Critical Going High | |
|
|
| • Upper |
14