Error Code

Message Information

 

 

Details

An error was reported during a SD card read or write.

 

Action

Reseat the flash media. If the problem persists, see Getting Help.

RFM1014

Message

Removable Flash Media <name> is write protected.

 

 

LCD Message

Removable Flash Media <name> is write protected. Check SD Card.

 

Details

The card is write-protected by the physical latch on the SD card. A

 

 

write-protected card cannot be used.

 

Action

If unintended, remove the media and disable write protection.

RFM1201

Message

Internal Dual SD Module redundancy is lost.

 

 

LCD Message

Internal Dual SD Module redundancy is lost. Check SD Card.

 

Details

Either one or both the SD cards are not functioning properly.

 

Action

See Getting Help.

RFM2001

Message

Internal Dual SD Module <name> is absent.

 

 

LCD Message

Internal Dual SD Module <name> is absent. Check SD Card.

 

Details

The SD card module is not detected or not installed.

 

Action

If unintended, reinstall the SD module.

RFM2002

Message

Internal Dual SD Module <name> is offline.

 

 

Details

The SD card module is installed but may be improperly installed or

 

 

configured incorrectly.

 

Action

Reinstall the SD module.

RFM2004

Message

Failure detected on Internal Dual SD Module <name>.

 

 

LCD Message

Internal Dual SD Module <name> failed. Check SD Card.

 

Details

The SD card module is installed but improperly configured or failed to

 

 

initialize.

 

Action

Reinstall the SD module and remove and reinstall SD cards.

RFM2006

Message

Internal Dual SD Module <name> is write protected.

 

 

Details

The module is write-protected. Changes may not be written to the

 

 

media.

 

Action

If unintended, remove the media and disable write protection.

136

Page 136
Image 136
Dell E19S, R520 RFM1014 Message, RFM1201 Message, RFM2001 Message, RFM2002 Message, RFM2004 Message, RFM2006 Message