Error Code

Message Information

 

 

Action

Re-configure system to the minimum supported configuration. If

 

 

issues persists, contact support.

TMP0118

Message

The system inlet temperature is less than the lower warning

 

 

 

threshold.

 

LCD Message

System inlet temperature is outside of range.

 

Details

Ambient air temperature is too cool.

 

Action

Check the system operating environment.

TMP0119

Message

The system inlet temperature is less than the lower critical threshold.

 

 

LCD Message

System inlet temperature is outside of range.

 

Details

Ambient air temperature is too cool.

 

Action

Check the system operating environment.

TMP0120

Message

The system inlet temperature is greater than the upper warning

 

 

 

threshold.

 

LCD Message

System inlet temperature is outside of range.

 

Details

Ambient air temperature is too warm or one or more fans may have

 

 

failed.

 

Action

Check the system operating environment and review event log for fan

 

 

failures.

TMP0121

Message

The system inlet temperature is greater than the upper critical

 

 

 

threshold.

 

LCD Message

System inlet <name> temperature is outside of range. Check Fans.

 

Details

Ambient air temperature is too warm or one or more fans may have

 

 

failed.

 

Action

Check the system operating environment and review event log for fan

 

 

failures.

VLT0204

Message

The system board <name> voltage is outside of the allowable range.

 

 

LCD Message

System board voltage is outside of range.

 

Details

System hardware detected an over voltage or under voltage

 

 

condition.

If multiple voltage exceptions occur consecutively the system may power down in fail-safe mode.

138

Page 138
Image 138
Dell E19S, R520 owner manual Issues persists, contact support, Failed, Failures, TMP0121 Message, VLT0204 Message