The Configuration Manager for the ICU identifies problems following the system boot routine and generates messages if necessary. These messages alert you to any unsuccessful attempts to configure Plug and Play or Peripheral Component Inter- connect (PCI) expansion cards, as well as any problems that interfere with the operation of the Configuration Manager. If you receive a message from the Configura- tion Manager, see Table C-2 for suggestions on resolving any problems indicated by the message.

7DEOH￿&￿￿￿￿￿&RQILJXUDWLRQ￿0DQDJHU￿0HVVDJHV ￿￿￿￿

0HVVDJH

3UREDEOH￿&DXVH

&RUUHFWLYH￿$FWLRQ

 

 

 

)RXQG￿3OXJ￿DQG￿3OD\￿ ,6$￿FDUG￿￿3OXJ￿DQG￿3OD\￿ ,6$￿&DUG￿1DPH￿

This message appears at

Status message; no action is required.

system start-up for each

 

Plug and Play ISA expan-

 

sion card recognized by

 

the Configuration

 

Manager.

 

127,&(￿￿%RRW￿'HYLFH￿

A boot device was found

Status message; no action is required. The

1RW￿$FWLYH￿￿&61 &DUG￿

to be inactive.

Configuration Manager automatically config-

6HOHFW￿1XPEHU￿

 

ures and activates the device.

 

 

 

2QH￿RU￿PRUH￿DFWLYH￿

You modified the

Reboot the system to reconfigure the card(s).

GHYLFHV￿KDYH￿EHHQ￿

resource values of one or

 

UHFRQILJXUHG￿￿￿￿V\V￿

more PCI or Plug and Play

 

WHP￿UHTXLUHV￿UHERRW￿￿

ISA expansion cards.

 

3UHVV￿DQ\￿NH\￿WR￿

 

 

UHERRW￿V\VWHP￿

 

 

7KH￿3OXJ￿DQG￿3OD\￿,6$￿

The Configuration Man-

FDUG￿KDV￿EHHQ￿VXFFHVV￿

ager has successfully

IXOO\￿FRQILJXUHG￿

configured the given

 

number of cards.

&DUG￿&RXQW￿3OXJ￿DQG￿

 

3OD\￿,6$￿FDUGV￿KDYH￿

 

EHHQ￿VXFFHVVIXOO\￿

 

FRQILJXUHG￿

 

If this message does not match the number of Plug and Play ISA expansion cards installed in your computer, reinstall any Plug and Play expansion cards not listed and reboot the system.

(5525￿￿,QVXIILFLHQW￿&0￿

There is not enough

0HPRU\

memory available to the

 

Configuration Manager

 

for it to run.

Disable any TSR programs or any unneeded device drivers.

(5525￿￿)DWDO￿%,26￿ HUURU￿,QWHUQDO￿(UURU￿ &RGH￿

A BIOS call failed with an internal error. The most likely cause is an incom- patibility between the BIOS and the Configura- tion Manager.

See the chapter titled “Getting Help” in your Diagnostics and Troubleshooting Guide for instructions on obtaining technical assistance.

NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary.