During cooking or the pyrolysis cycle.

1.30 F0 or 30 F1 appear during the cooking or pyrolysis

cycle

 Oven temperature sensor broken or not working properly.

The cooling fan stays on and if the pyrolysis cycle is in pro-

gress the door remains locked.

What to do:

1. Turn the oven function selector to 0 (oven OFF). A 30 mi- nute countdown will start. If the selector is turned and then returned to 0 the count will start again from 30.

2. Wait for the countdown to finish.

 The fan switches off and the door, if locked, unlocks.

3. Disconnect the oven from the mains and contact the After- Sales Service Centre because the oven can no longer be used.

Caution: If the function selector is not turned to 0 (oven OFF), the cooling fan will continue to work and the oven door, if locked, remains locked.

2.do.Lo appears during the pyrolysis cycle

2a There has been a black-out

 The oven door is locked. The programmer is zeroed and the Pyrolysis cycle cancelled.

What to do:

1.Turn the oven function selector to 0 (oven OFF).

2.Wait for the oven cavity to cool down. When the temperatu- re has dropped 12.00 will flash on the display.

3.Start again and set the programmer time.

4.Start the pyrolysis cycle again.

2b The oven function selector has been moved from the Pyrolysis function to a cooking function.

The Pyrolysis cycle is cancelled. What to do:

1.Wait for the door to unlock. This happens automatically when the temperature inside the oven has dropped below 300 °C; P0.00 will appear with P flashing.

2.Turn the function selector to 0 (oven OFF).

3.Repeat the operations to start the pyrolysis cycle.