REPLACING THE POWER SUPPLY CABLE

REPLACING THE POWER SUPPLY CABLE

Important! This appliance must be connected to the electricity supply only by an authorised person.

To connect the supply cable:

■■ Unhook the terminal board cover by inserting a screwdriver into the two hooks “A” (fig. 5).

■■ Open the cable gland by unscrewing screw “F” (fig. 6), unscrew the terminal screws and remove the cable.

■■ The new supply cable, of suitable type and section, is connected to the terminal board following the diagram fig. 7.

■■ Close and hook again the terminal board cover.

N.B. The earth conductor must be left about 3 cm longer than the others.

VOLTAGE AND POWER CONSUMPTION

220-240 V ac

3095 W (13.45 A)

FEEDER CABLE SECTION

TYPE H05RR-F

3 x 1,5 mm2 (*) (**)

(*)Connection possible with plug and outlet (**) Connection with wall box connection.

Figure 5

A

Figure 6

F

Figure 7