Desa GVR65BPA, GVR65PA, GVR50PA, GVR35PA, GVR50BPA installation manual Installing Heater, Continued

Models: GVR65BPA GVR35PA GVR50PA GVR50BPA GVR65PA

1 44
Download 44 pages 11.47 Kb
Page 12
Image 12
Use pipe joint sealant that is resistant to liquid petro- leum (LP) gas.

INSTALLING HEATER

Continued

Installation must include a manual shutoff valve, ground joint union, plugged 1/8" NPT tap and a sediment trap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION

WARNING ICON

G 001

Use pipe joint sealant that is resistant to liquid petro- leum (LP) gas.

Install sediment trap in supply line as shown in Figure 7. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

IMPORTANT: Use two pipe wrenches when connecting gas piping to gas control valve of heater. This will prevent turning or damaging control valve.

Control

Valve

Ground

Joint

Union

 

 

Reducer

 

 

 

Bushing to

 

Test

 

1/8" NPT

 

 

1/8" NPT

 

Gauge

 

 

 

Plug Tap

Connection*

 

 

Tee Joint

 

 

Sediment

 

 

Trap

Acceptable construction of inlet gas line

 

From External

 

Regulator (11"

Manual

W.C. Min** to

14" W.C. Max)

Shutoff

 

Valve *

 

 

Preferred

 

construction

 

of inlet gas

 

line

 

From

Tee Joint

External

Regulator

Pipe

(11" W.C.

Min** to

Nipple

14" W.C.

 

Cap

Max)

 

12

Figure 7 - Gas Connection

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 37.

**For purposes of input adjustment.

100791

Page 12
Image 12
Desa GVR65BPA, GVR65PA Installing Heater, Continued, Use pipe joint sealant that is resistant to liquid petro- leum LP gas