Desa GVR65PA Technical Service, Service Hints, Specifications, 35,000 BTU/Hr, 50,000 BTU/Hr

Models: GVR65BPA GVR35PA GVR50PA GVR50BPA GVR65PA

1 44
Download 44 pages 11.47 Kb
Page 35
Image 35
TECHNICAL

TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE

HINTS

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

 

35,000 BTU/Hr

50,000 BTU/Hr

65,000 BTU/Hr

 

Model

Model

Model

BTU

35,000

50,000

65,000

Type Gas

Propane Only

Propane Only

Propane Only

Ignition

Piezo

Piezo

Piezo

Pressure Regulator Setting 10.5" W.C.

10.5" W.C.

10.5" W.C.

Inlet Gas Pressure

 

 

 

Maximum

14" W.C.

14" W.C.

14" W.C.

Minimum

11" W.C.

11" W.C.

11" W.C.

Dimensions, Inches

 

 

 

Heater (H x W x D)

25 x 27 1/4 x 16

27 x 32 1/2 x 16

31 x 37 3/4 x 16

Shipping Weight (pounds) 97

133**/120

158**/145

Flue Vent Size

4" dia.

4" dia.

5" dia.

Orifice Size

52 drill, ø .0635

46 drill, ø .081

2.4 mm, ø .0945

** When equipped with blower

Note: These heaters are certified for elevations of 0-4500 feet above sea level. For elevations above 2000 feet, de-rate heater 4% for each 1000 feet above sea level.

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane gas supply may be low

When gas quality is bad

pilot will not stay lit

burner will produce yellow flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.

100791

35

Page 35
Image 35