TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

 

Slight smoke or odor during initial

1.

Not enough air

1.

Check burner for dirt and

operation

 

 

 

debris. If found, clean burner

Moisture/condensation noticed

 

 

 

(see Cleaning and Mainte-

2.

Gas regulator defective

 

nance, page 24)

on windows

2.

Replace gas control

 

 

3.

Residues from manufacturing

3.

Problem will stop after a few

 

 

 

processes and logs curing

 

hours of operation

 

 

 

 

 

 

Heater produces a whistling noise

1.

Not enough combustion/ven-

1.

Refer to Air for Combustion

when burners are lit

 

tilation air

 

and Ventilation requirements

 

 

 

 

 

(page 5)

 

 

 

 

 

 

 

 

1.

Turning control knob to HI po-

1.

Turn control knob to LO

 

 

 

sition when burners are cold

 

position and let warm up for

 

 

2.

Air in gas line

 

a minute

 

 

2.

Operate burners until air is

 

 

 

 

 

removed from line. Have gas

 

 

 

 

 

line checked by local natural

 

 

3.

Air passageways on heater

 

or propane/LP gas company

 

 

3.

Observe minimum installation

 

 

 

blocked

 

clearances (see page 9)

 

 

4.

Dirty or partially clogged

4.

Clean burners (see Cleaning

 

 

 

burner orifice(s)

 

and Maintenance, page 24)

 

 

 

 

 

or replace burner orifice(s)

 

 

 

 

 

 

White powder residue forming

1.

When heated, vapors from

1.

Turn heater off when using

within burner box or on adjacent

 

furniture polish, wax, carpet

 

furniture polish, wax, carpet

walls or furniture

 

cleaners, etc. may turn into

 

cleaners or similar products

 

 

 

white powder residue

 

 

 

 

 

 

 

 

 

Remote does not function

1.

Battery is not installed. Bat-

1.

Replace 9-volt batteries in

 

 

 

tery power is low

 

receiver and remote control

 

 

 

 

 

Fireplace produces a clicking/

1.

Metal expanding while heating

1.

This is common with most heat-

ticking noise just after burner is

 

or contracting while cooling

 

ers. If noise is excessive, contact

lit or shut off

 

 

 

qualified service person

111604-01L