INSTALLATION
Continued
INSTALLING HOOD
Install hood to top of firebox as shown in Figure 5. Use 3 Phillips screws provided
Figure 5 - Installing Hood to Firebox
ASSEMBLING AND ATTACHING OPTIONAL TRIM (Included with Mantel Accessory)
IMPORTANT: If you are recessing the firebox in a wall, do not attach trim at this time. See page 11. Note: The instructions below show assembling and attaching trim to fireplace.
1.Remove packaging from three pieces of trim.
2.Locate four brass screws, two adjusting plates with set screws and two shims in the hardware packet.
3.Align shim under adjusting plate as shown in Figure 6.
4.Slide one end of adjusting plate/shim in slot on mitered edge of top trim (see Figure 6).
5.Slide other end of adjusting plate/shim in slot on mitered edge of side trim (see Figure 6).
6.While firmly holding edges of trim together, tighten both set screws on the adjusting plate with slotted screwdriver.
7.Repeat steps 1 through 6 for other side.
8.Tighten trim hanging screws (#10 x 6.25 shoulder) into holes in cabinets. Place the assembled trim onto fireplace cabinet. Align hanging notches on trim with hanging screws on side of fireplace (see Figure 7). Push trim firmly into place, sliding hanging notches over hanging screws.
Set Screws
Side Trim | Adjusting | Top Trim | |
Plate | |||
|
Trim
Hanging
Screws
Hanging
Notches
on Trim
Assembled
Trim
Figure 7 - Attaching Trim to Fireplace INSTALLATION CLEARANCES
WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining wall.
Carefully follow the instructions below. This will ensure safe installation.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A.Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 8.
Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace opening (see Figure 8).
B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Top | Left and | Bottom |
| Right Sides | and Rear |
42" | 16" | 0" |
| Example |
|
Mitered | Shim |
Slot Edge | Slot |
|
Figure 6 - Assembling Trim
*
*Minimum 16 inches from Side Wall
Figure 8 - Minimum Clearance for Combustible to Wall
www.desatech.com | 9 |