SPECIFICATIONS
| LMFP33NR(A) | LMFP33PR(A) |
Btu (Variable) | 23,000/33,000 | 23,000/33,000 |
Type Gas | Natural Gas | Propane/LP |
Ignition | Piezo | Piezo |
Pressure Manifold | 3.5" W.C. | 7.9" W.C. |
Inlet Gas Pressure (in. of water) |
|
|
Maximum | 10.5" | 14" |
Minimum* | 5.5" | 11" |
Shipping Weight | 122 lbs. | 122 lbs. |
* For input adjustment |
|
|
WIRING DIAGRAM
SERVICE HINTS
When Gas Pressure Is Too Low
•pilot will not stay lit
•burner will have delayed ignition
•fireplace will not produce specified heat
•for propane/LP unit, propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local gas supplier.
Red
Black | White |
| Red |
TECHNICAL SERVICE
You may have further questions about installation, operation or troubleshooting. If so, contact DESA Heating ProductsʼTechnical Service Department at
You can also visit DESA Heating Productsʼtechni- cal services web site at www.desatech.com.
REPLACEMENT PARTS
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Heating Productsʼ Technical Service Department at
•your name and address
•model and serial numbers of your fireplace
•how fireplace was malfunctioning
•type of gas used (propane/LP or natural gas)
•purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they canʼt supply original replacement part(s), call DESA Heating Products at
•model number of your fireplace
•the replacement part number
www.desatech.com | 29 |