OWNER’S MANUAL
VENTING INSTALLATION
Continued
CHIMNEYS
•Complete familiarity with chimney con- dition, height, size, clearance to combus- tibles and other factors is essential.
NOTICE: Consult the authority having jurisdiction in your area regarding masonry chimney vent- ing applications.
NOTICE: A complete chimney inspection by a qualified person should be performed.
•Appliances using
•Oversized chimneys should be relined with appropriate listed relining systems.
•Cleanout access may be required.
RELINING SYSTEMS
•Suitability and approval of relining ma- terials should be determined.
•Condition, size, height, and termina- tion of the chimney to be relined must be determined.
•No substitution of components should be made.
•Joints and connectors should be made according to manufacturer’s instructions.
NOTICE: Consult the authority having jurisdiction in your area regarding listed chimney liner venting applications.
WARNING: Operation of im- properly installed and maintained venting system could result in serious injury, property damage, or loss of life.
HIGH ALTITUDE
INSTALLATION
Your Sun Valley
When installing this stove and burner sys- tem at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner ori- fice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification and proper orifice for your location.
When installing this fireplace at an eleva- tion above 4500 feet (in Canada), check with local authorities.
For assistance with any high altitude installa- tion contact DESA International’s Technical Service Department at
Figure 29 - Typical Straight Installation with Listed Chimney Liner
Figure 28 - Straight Installation into |
|
Masonry Chimney | Continued |
106706 | 11 | For more information, visit www.desatech.com |